PURPOSE To investigate the feasibility of correcting ocular higher order aberrations (HOAs) in keratoconus (KC) using wavefront-guided optics in a scleral lens prosthetic device (SLPD). METHODS Six advanced KC patients (11 eyes) were fitted with an SLPD with conventional spherical optics. A custom-made Shack-Hartmann wavefront sensor was used to measure aberrations through a dilated pupil wearing the SLPD. The position of SLPD, that is, horizontal and vertical decentration relative to the pupil and rotation were measured and incorporated into the design of the wavefront-guided optics for the customized SLPD. A submicron-precision lathe created the designed irregular profile on the front surface of the device. The residual aberrations of the same eyes wearing the SLPD with wavefront-guided optics were subsequently measured. Visual performance with natural mesopic pupil was compared between SLPDs having conventional spherical and wavefront-guided optics by measuring best-corrected high-contrast visual acuity and contrast sensitivity. RESULTS Root mean square of HOA in the 11 eyes wearing conventional SLPD with spherical optics was 1.17 ± 0.57 μm for a 6-mm pupil. Higher order aberrations were effectively corrected by the customized SLPD with wavefront-guided optics, and root mean square was reduced 3.1 times on average to 0.37 ± 0.19 μm for the same pupil. This correction resulted in significant improvement of 1.9 lines in mean visual acuity (p < 0.05). Contrast sensitivity was also significantly improved by factors of 2.4, 1.8, and 1.4 on average for 4, 8, and 12 cycles/degree, respectively (p < 0.05 for all frequencies). Although the residual aberration was comparable to that of normal eyes, the average visual acuity in logMAR with the customized SLPD was 0.21, substantially worse than normal acuity. CONCLUSIONS The customized SLPD with wavefront-guided optics corrected the HOA of advanced KC patients to normal levels and improved their vision significantly.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scleral lens influence on corneal curvature and pachymetry in keratoconus patients.

OBJECTIVES To investigate the influence of full scleral lenses on corneal curvature and pachymetry in keratoconus patients. METHODS In this intervention study, 20 eyes of 14 patients were measured by Scheimpflug imaging (Pentacam HR, Oculus) at two time points: directly and ≥1 week after scleral lens removal. Steep, flat and maximal keratometry (K(steep), K(flat) and K(max)) and optical pachy...

متن کامل

Scleral lens tolerance after corneal cross-linking for keratoconus.

PURPOSE Subjective and objective evaluation of scleral lens tolerance and fitting before and after corneal cross-linking (CXL) for progressive keratoconus. METHODS In this prospective cohort, evaluations were made of 18 unilateral eyes in patients who underwent CXL and had been wearing scleral lenses before the procedure. All the patients gave informed consent; they were able to cooperate wit...

متن کامل

Scleral lenses in the management of keratoconus.

PURPOSE To describe the use of Jupiter scleral lenses (Medlens Innovations, Front Royal, VA; and Essilor Contact Lenses, Inc., Dallas, TX) in the management of keratoconus. METHODS We performed a single-center retrospective chart review of our initial 32 patients with keratoconus evaluated for scleral lens wear. All patients were referred for scleral lens evaluation after exhausting other non...

متن کامل

Scleral lens for keratoconus: technology update.

Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. These lenses are inserted in the eyes after filling with sterile isotonic fluid. Generally, scleral contact lenses are used for high irregular astigmatis...

متن کامل

Jupiter Scleral Lenses: the UC Davis Eye Center experience.

PURPOSE The aim of this study was to evaluate both the indications for and results of fitting the Jupiter Scleral Lens in patients with corneal abnormalities. METHOD This was a retrospective case review of 63 patients (107 eyes) fitted with scleral lenses between October 2009 and March 2011 at the UC Davis Eye Center. RESULTS Sixty-three percent of 107 eyes were in patients with keratoconus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 90 4  شماره 

صفحات  -

تاریخ انتشار 2013