A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.
منابع مشابه
A Study of Electromagnetic Radiation from Monopole Antennas on Spherical-Lossy Earth Using the Finite-Difference Time-Domain Method
Radiation from monopole antennas on spherical-lossy earth is analyzed by the finitedifference time-domain (FDTD) method in spherical coordinates. A novel generalized perfectly matched layer (PML) has been developed for the truncation of the lossy soil. For having an accurate modeling with less memory requirements, an efficient "non-uniform" mesh generation scheme is used. Also in each time step...
متن کاملCoupling Effects and Performance of Loran Transmitter Antennas
It is known that if a conductor resides in the neighboring of an antenna with a small distance relative to the wavelength, it induces a reverse current on the conductor. This paper involves the unavoidable coupling effects on some common types of LF antennas, due to the large wavelength in this frequency band. In particular, after some discussions about top-loaded antennas, the coupling effect ...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملهینهسازی مسیر هادیهای انتقال در محفظه فلزی تجهیزات الکتریکی مبتنی بر سازگاری الکترومغناطیسی با استفاده از روش تصمیمگیری چند معیاره مطالعه موردی: سیستم تزریق جریان 25 کیلو آمپر
The higher frequency transient signals generated as a result of a power system fault or disturbance provide the basis for an alternative approach to power system containing connectors and cables result in unsuitable operation of the system. However one major challenge is the need to ensure that the transients to be neutralized by electromagnetic compatibility (EMC) issues and cabling routes. T...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...