Nasal continuous positive airway pressure for nonapneic snoring?
نویسندگان
چکیده
The feasibility of nasal continuous positive airway pressure (CPAP) for heavy snoring associated with daytime sleepiness was studied in 118 consecutive patients with an apnea hypopnea index below 5. Fifty-nine of them reported daytime sleepiness in a questionnaire and were offered treatment with nasal CPAP. Whereas 48 patients refused it, the remaining 11 (19%) accepted nasal CPAP for home therapy. Acceptors and refusers did not differ in sleep structure, but acceptors had slightly more sleep-disordered breathing events per hour of sleep than refusers. The pressure needed to abolish snoring in these 11 patients was 7.3 +/- 1.6 cm H2O. Six months after prescription, the built-in time counters of the patients' devices were read. By dividing the hours of operation by the days since initiation of treatment, we found a mean daily use time of only 2.8 +/- 1.5 h. Nevertheless, eight patients (73%) reported that their sleepiness had improved with therapy. We conclude that only a minority of nonapneic snorers accept treatment with nasal CPAP on a long-term basis and that this subgroup is not predictable from polysomnography.
منابع مشابه
Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications.
Treatment of obstructive sleep apnea with nasal continuous positive airway pressure mandates simultaneous increases of both inspiratory and expiratory positive airway pressures to eliminate apneas as well as nonapneic oxyhemoglobin desaturation events. We hypothesized that the forces acting to collapse the upper airway during inspiration and expiration are of different magnitudes and that obstr...
متن کاملSnoring detection during auto-nasal continuous positive airway pressure.
A bench study using an artificial lung model was performed to evaluate the snoring detection sensitivity of six (commercially available) auto-nasal continuous positive airway pressure (NCPAP) devices. Snoring was simulated by a loudspeaker connected to the lung model and abruptly activated during 1 s of each inspiratory period to induce pressure oscillation. The oscillation frequencies chosen w...
متن کاملChanges in snoring characteristics after 30 days of nasal continuous positive airway pressure in patients with non-apnoeic snoring: a controlled trial.
BACKGROUND A study was performed to evaluate the effect of discontinuation of nasal continuous positive airway pressure (NCPAP) treatment on snoring characteristics. METHODS Eighteen non-apnoeic snoring subjects were randomly allocated to either a no treatment control group or an NCPAP treatment group. The control group was studied twice (baseline and day 30 of follow up). In the NCPAP group ...
متن کاملComparison of Nasal Continuous Positive Airway Pressure Therapy with and without Prophylactic Surfactant in Preterm Neonates
Background: Preterm labor is at risk for respiratory distress syndrome (RDS) and sometimes requires to mechanical ventilation (MV) and surfactant therapy. Continuous positive airway pressure (CPAP) and Nasal Continuous positive airway pressure (NCPAP) are the methods of respiratory support especially for using in RDS of neonates. In other method surfactant is administered to babies via tracheal...
متن کاملEvaluation of an auto-nCPAP device based on snoring detection.
We evaluated an auto-nasal continuous positive airway pressure (nCPAP) prototype (MC+; SEFAM, Nancy, France) in which apnoea/hypopnoea detection was disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The device was tested in 15 previously untreated obstructive sleep apnoea patients during a night with polysomnography. We observed that a single night of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 107 1 شماره
صفحات -
تاریخ انتشار 1995