Practical considerations on the determination of the accuracy of the lattice parameters measurements from digital recorded diffractograms.

نویسندگان

  • Johannes Biskupek
  • Ute Kaiser
چکیده

The influence of magnification and defocus on the precision Delta d/d of lattice parameter measurements have been studied by evaluating the diffraction vector length and the signal-to-noise ratio (SNR) of the diffraction peaks in diffractograms calculated by fast Fourier transformation (FFT) of digitally recorded images. Examples are perfect crystals (Si and SiC) and defective crystals (two- and three-dimensional defects within SiC). It is shown that the precision is independent of the diffuseness of the FFT reflections caused by defocus changes or by two-dimensional defects. For the case of a perfect and/or a defective but unstrained crystal, the precision Delta d/d is linearly dependent on the diffraction vector length. For optimal conditions, the highest precision is 0.002. For a defective crystal containing precipitates (nanocrystals), it was found for both the matrix and the nanocrystals that the precision of the measurement is determined by the contribution of strain value (Delta d/d)(strain) of the defective crystal and accuracy Delta d/d for the perfect matrix crystal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements

Background and Purpose:  Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...

متن کامل

Implementation of D3Q19 Lattice Boltzmann Method with a Curved Wall Boundary Condition for Simulation of Practical Flow Problems

In this paper, implementation of an extended form of a no-slip wall boundary condition is presented for the three-dimensional (3-D) lattice Boltzmann method (LBM) for solving the incompressible fluid flows with complex geometries. The boundary condition is based on the off-lattice scheme with a polynomial interpolation which is used to reconstruct the curved or irregular wall boundary on the ne...

متن کامل

Investigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

Measurements of iron concentrate stockpile weight, from laser mapping to investigation of effective parameters on surface density

Determination of stockpile weight and stockpile inventory are critical to any quarry or mining operation, whether it is required by accounting firms or used internally for the quarterly balance of production and sales. Generally, errors and problems originate from two factors. Volume of stockpile that is traditionally worked out from the mapping results has a low accuracy due to irregular shape...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of electron microscopy

دوره 53 6  شماره 

صفحات  -

تاریخ انتشار 2004