Regions of interest in the venous sinuses as input functions for quantitative PET.

نویسندگان

  • L M Wahl
  • M C Asselin
  • C Nahmias
چکیده

UNLABELLED As clinical PET becomes increasingly available, quantitative methods that are feasible in busy clinical settings are becoming necessary. We investigated the use of intracranial blood pools as sources of an input function for quantitative PET. METHODS We studied 25 patients after the intravenous injection of [18F]6-fluoro-L-m-tyrosine and compared sampled blood time-activity curves with those obtained in small regions of interest (ROIs) defined in the blood pools visible in the PET images. Because of the comparatively large dimensions of the blood pool at the confluence of the superior sagittal, straight and transverse sinuses, a venous ROI input function was chosen for further analysis. We applied simple corrections to the ROI-derived time-activity curves, deriving expressions for partial volume, spillover and partition of tracer between plasma and red blood cells. The results of graphic and compartmental analysis using both sampled [Cs(t)] and ROI [Cr(t)] venous input functions for each patient were compared. We also used an analytic approach to examine possible differences between venous and arterial input functions in the cerebral circulation. RESULTS Cr(t) peaked significantly earlier and higher than Cs(t) in this patient population, although the total integral under the curves did not differ significantly. We report some apparent differences in the results of modeling using the two input functions; however, neither the graphically determined influx constant, Ki, nor the model parameter that reflects presynaptic dopaminergic metabolism, k3, differed significantly between the two methods. The analytic results suggest that the venous ROI input function may be closer to the arterial supply of radiotracer to the brain than arterialized venous blood, at least in some patient populations. CONCLUSION We present a simple method of obtaining an input function for PET that is applicable to a wide range of tracers and quantitative methods and is feasible for diagnostic PET imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Improved quantification of salivary gland scintigraphy by means of factor analysis

Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...

متن کامل

Validation of a less-invasive method for measurement of serotonin synthesis rate with alpha-[11C]methyl-tryptophan.

We tested in normal human subjects a less invasive method to obtain plasma input function required in the calculation of the brain serotonin synthesis rate measured with positron emission tomography (PET) and alpha-[11C]methyl-tryptophan (alpha-MTrp). The synthesis rates derived with the arterial input function were compared to those derived from venous plasma and venous sinus time-radioactivit...

متن کامل

Minimally invasive method of determining blood input function from PET images in rodents.

UNLABELLED For cardiovascular research on rodents, small-animal PET has limitations because of the inherent spatial resolution of the system and because of cardiac motion. A factor analysis (FA) technique for extracting the blood input function and myocardial time-activity curve from dynamic small-animal PET images of the rodent heart has been implemented to overcome these limitations. METHOD...

متن کامل

Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system.

UNLABELLED Measurement of the arterial input function is essential for quantitative assessment of physiological function in vivo using PET. However, frequent arterial blood sampling is invasive and labor intensive. Recently, a PET system has been developed that consists of two independent PET tomographs for simultaneously scanning the brain and heart, which should avoid the need for arterial bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 40 10  شماره 

صفحات  -

تاریخ انتشار 1999