Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture.

نویسندگان

  • Daniel Calladine
  • Vaughan Tanner
چکیده

PURPOSE To evaluate the effects of stromal hydration on clear corneal incision (CCI) architecture immediately after surgery using anterior segment optical coherence tomography (AS-OCT). SETTING Department of Ophthalmology, Royal Berkshire Hospital, Reading, United Kingdom. METHODS Clear corneal incisions in adult eyes were examined using a Visante AS-OCT imaging system within 1 hour of surgery. Half the CCIs had stromal hydration with a balanced salt solution and half did not. Incisions were made with a 2.75 mm steel keratome. Intraocular pressure (IOP) was measured within 90 minutes after surgery. The CCI length and corneal thickness at the CCI site were measured using software built into the AS-OCT system. RESULTS Thirty CCIs were evaluated. Stromal hydration significantly increased the measured CCI length (P<.05, t test); this was the result of a trend toward increased corneal thickness at the CCI site with hydration (P<.1, t test). The mean CCI length was 1.69 mm +/- 0.27 (SD) (range 1.31 to 2.32 mm) with hydration and 1.51 +/- 0.23 mm (range 1.30 to 1.95 mm) without hydration. The mean IOP was 20.9 +/- 8.18 mm Hg and 15.8 +/- 8.20 mm Hg, respectively. The IOP tended to be higher with hydration (P<.1, t test). Local detachment of Descemet membrane was more likely with stromal hydration (63%) than without (25%). CONCLUSION Stromal hydration significantly increased CCI length and tended to leave the eye with a higher early postoperative IOP, showing the importance of taking stromal hydration into account when designing similar OCT studies of CCI architecture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Stromal Hydration of Clear Corneal Incisions

D r. Vasavada regularly performs stromal hydration, at both the clear corneal temporal incision and paracentesis, as part of his strategy for sealing the wound after cataract surgery. Further, he has found stromal hydration to be a useful adjunct in clear corneal cataract surgery, because it allows the adequate approximation of the anterior and posterior aspects of the corneal tunnel. Today, su...

متن کامل

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING Private practice, Eugene, Oregon, USA. METHODS The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postop...

متن کامل

Structural Analysis of Different Incision Sizes and Stromal Hydration in Cataract Surgery Using Anterior Segment Optical Coherence Tomography

PURPOSE To analyze healing changes of corneal wounds of different corneal incision sizes with or without stromal hydration in cataract surgery using anterior segment optical coherence tomography. METHODS Cataract surgeries were performed by a single surgeon and 2.2- and 2.8-mm corneal incisions were made using a diamond blade (ME-759; Meyco, Biel-Bienne, Swiss). Patients were divided into fou...

متن کامل

Factors affecting stromal hydration of clear corneal incision architecture.

Factors affecting stromal hydration of clear corneal incision architecture We have some comments about the article by Calladine et al. thatwewould like to sharewith the authors. First, one factor thatmight cause the difference in architecture betweenhydrated clear corneal incisions (CCIs) and nonhydrated CCIs is the corneal stromal edema at the incision site induced by hydration. The authors mi...

متن کامل

Imaging and investigating the effects of incision angle of clear corneal cataract surgery with optical coherence tomography.

Effects of incision angle in construction of clear corneal cataract incision are studied with optical coherence tomography (OCT). A stable incision angle range is found to be existent for single-planed, clear corneal cataract incisions. When well pressurized, incision angles within this stable range result in well-apposed incision edges that resist gapping while incision angles falling outside ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 35 8  شماره 

صفحات  -

تاریخ انتشار 2009