Comparison of B1 Field Homogeneity for Shielded Birdcage, TEM and Microstrip Volume Coils at 300MHz
نویسندگان
چکیده
Introduction: Because of the inherent advantage of improved SNR, ultra-high field (3T~9.4T) MRI technology and applications have been accelerated these years. However many engineering challenges have arisen from high-operation frequencies. One major challenge is the difficulty of designing large-size RF coils with high-resonance frequencies. In addition, it has been shown that the homogeneity of the radio frequency (RF) magnetic field, B1, will progressively decrease in large samples with increasing B1 frequency. This is mainly caused by the dielectric resonance phenomenon [1]. Due to distributed element and intrinsic shield, TEM [2] and microstrip [3] volume coils can be used for very high field. Improved birdcage coil with tight RF shield, widening rung, etc. also can be used and reported at 7T [4]. In order to reveal which one has better B1 homogeneity these three kinds of volume coils were simulated and compared by FDTD method in this work.
منابع مشابه
SAR and B1 Field in a Human Head Model for Birdcage, TEM and Microstrip Coils at 7T
Introduction: The advantage of high field MRI is high SNR which can increase image resolution or decrease acquisition time. However, there are some challenges, such as the RF wavelength effect and the power deposition in tissues. A comparison of three different volume coils loaded with the same spherical homogeneous phantom has been reported [1]. In order to mimic the B1 field distribution and ...
متن کاملNumerical Comparison Between TEM Head Coil and Birdcage Head Coil at 7T
G. D. DeMeester, Z. Zhai, M. A. Morich, C. Leussler, C. Findeklee Philips Medical Systems, Cleveland, Ohio, United States, Philips Research Laboratories, Hamburg, Hamburg, Germany Introduction A TEM T/R head coil and a shielded birdcage T/R head coil operated at 298MHz/7T were both modeled using the Finite Difference Time Domain (FDTD) method. The two coils have approximately the same physical ...
متن کاملA Method for Accurate Calculation of B1 Fields in Three Dimensions. Effects of Shield Geometry on Field Strength and Homogeneity in the Birdcage Coil
A method for calculating B1 field strength and homogeneity In order to construct an optimal RF system, it is important as functions of radiofrequency shield geometry is presented. The to consider how shield geometry will affect the performance method requires use of three-dimensional finite-element analysis, of the RF system. It is possible to measure B1 field strength birdcage-coil theory, and...
متن کاملDouble Tuned 31P/1H Elliptical Transceiver Phased Array for the Human Brain Studies at 7 T
Introduction: The improved SNR at 7T provides significant advantages for both H and lower gyromagnetic nuclei such as P, Na and C (X nuclei). Double resonant volume head coils, based on both birdcage (1-3) and TEM (4) designs have been previously used at lower magnetic fields. However at 7T, transceiver phased arrays provide significant advantages for both B1 homogeneity and transmit efficiency...
متن کاملMicrostrip Quasi-TEM Resonator for Magnetic Resonance Imaging at High Field of 8T
In this work, we used the finite element method (FEM) and the multiconductor transmission lines (MTL) method for designing an UHF magnetic resonance imaging (MRI) probe. This radio frequency (RF) volume coil quasi-transverse electromagnetic (quasi-TEM) type, based on the use of 16 microstrip transmission line elements has been developed for in vivo hydrogen magnetic resonance (HMR) application ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002