Bayesian dose-response analysis for epidemiological studies with complex uncertainty in dose estimation.

نویسندگان

  • Deukwoo Kwon
  • F Owen Hoffman
  • Brian E Moroz
  • Steven L Simon
چکیده

Most conventional risk analysis methods rely on a single best estimate of exposure per person, which does not allow for adjustment for exposure-related uncertainty. Here, we propose a Bayesian model averaging method to properly quantify the relationship between radiation dose and disease outcomes by accounting for shared and unshared uncertainty in estimated dose. Our Bayesian risk analysis method utilizes multiple realizations of sets (vectors) of doses generated by a two-dimensional Monte Carlo simulation method that properly separates shared and unshared errors in dose estimation. The exposure model used in this work is taken from a study of the risk of thyroid nodules among a cohort of 2376 subjects who were exposed to fallout from nuclear testing in Kazakhstan. We assessed the performance of our method through an extensive series of simulations and comparisons against conventional regression risk analysis methods. When the estimated doses contain relatively small amounts of uncertainty, the Bayesian method using multiple a priori plausible draws of dose vectors gave similar results to the conventional regression-based methods of dose-response analysis. However, when large and complex mixtures of shared and unshared uncertainties are present, the Bayesian method using multiple dose vectors had significantly lower relative bias than conventional regression-based risk analysis methods and better coverage, that is, a markedly increased capability to include the true risk coefficient within the 95% credible interval of the Bayesian-based risk estimate. An evaluation of the dose-response using our method is presented for an epidemiological study of thyroid disease following radiation exposure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

برآورد دوزهای هدف با استفاده از روش MCPMod در مطالعات دوز-پاسخ

Background and Objective: Determining adequate model and estimation of target dose with high precision is a key goal in dose-response studies. MCPMod is a new method that used for model selection and estimation of target doses and unlike other methods it does not have any limitation.  In this method, selection of models has performed by hypothesis testing also increasing responses that are a cr...

متن کامل

Pharmacokinetic studies and human absorbed dose estimation of 68Ga-(4 {[(bis (phosphonomethyl)) carbamoyl] methyl}-7,10-bis(carboxymethy l) -1,4,7,10-tetraazacyclododec-1-yl) acetic acid

Background: In this study, human absorbed dose of a newly introduced bone imaging agent, 68Ga-(4-{[(bis(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl)-1,4,7,10-tetraazacyclododec-1-yl) acetic acid (68Ga-BPAMD), was estimated based on the rats data. Materials and Methods: 68Ga was obtained from the 68Ge/68Ga generator and it's radionuclidic and radiochemical purities were investigate...

متن کامل

Determination of dose-response relationship in cultured human lymphocytes for biological dosimetry

Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...

متن کامل

A Bayesian Semiparametric Model for Radiation Dose-Response Estimation.

In evaluating the risk of exposure to health hazards, characterizing the dose-response relationship and estimating acceptable exposure levels are the primary goals. In analyses of health risks associated with exposure to ionizing radiation, while there is a clear agreement that moderate to high radiation doses cause harmful effects in humans, little has been known about the possible biological ...

متن کامل

Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams

Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Statistics in medicine

دوره 35 3  شماره 

صفحات  -