Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application.
نویسندگان
چکیده
A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.
منابع مشابه
Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملCardiac Imaging Using a Phased Array Ultrasound System
Underlying the conception and design of this new imaging system were severai design considerations specifically directed toward its application in clinical cardiology. These include image rates commensurate with cardiac dynamics, a field of view sufficiently large to allow image formation of most or all of the left ventricle, and the utilization of a relatively small, hand-held transducer which...
متن کاملCardiac imaging using a phased array ultrasound system. I. System design.
A new two-dimensional, real-time, high resolution ultrasound imaging system is described. This system uses a linear array of ultrasound transducers to generate tomographic images of the heart in a circular sector format. Phased array techniques allow rapid steering of the ultrasound beam so that images are produced at the rate of 20 per second, or more, while maintaining a resolution of 2-4 mm ...
متن کاملRenal denervation using externally delivered focused ultrasound: summary of clinical experience to date and validation of supporting computational simulations
Background/introduction The Kona Medical Surround SoundTM System is a fully non-invasive system for renal denervation which employs ultrasound based imaging for targeting and tracking as well as a phased array therapeutic ultrasound transducer. To date, 69 patients have been treated under three different protocols (WAVE I, WAVE II, and WAVE III). Follow up ranges from 3 months to over 2 years. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 53 2 شماره
صفحات -
تاریخ انتشار 1976