Post-mortem estimation of temperature distribution on a power transformer: Physicochemical and mechanical approaches
نویسندگان
چکیده
Power transformers are electrical machines that allow us to transport electric energy, with reduced losses, from generation stations to consumption points. This definition gives us an idea of the number of transformers that are used in power distribution systems worldwide. The main problem that may affect power transformers is the operation at high temperature. This paper summarizes the results of a postmortem temperature estimation carried out on an 800 kVA distribution transformer. Two methodologies are considered for estimating the temperature distribution in the windings of the machine. The first is based on the calculation of the degree of polymerization and the second is obtained from the tensile strength index. By knowing the value of these two magnitudes for a new and for an aged paper, and the period of operation of a transformer, the temperature distribution along the height of the windings can be estimated. None other previous works have used the tensile strength of winding paper for temperature distribution estimation. With these results and the loading regime records, similar transformers still in operation can be operated in an alternative manner and future designs can be improved. © 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملEffect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement
Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...
متن کاملExtraction Kinetics and Physicochemical Studies of Terminalia catappa L Kernel Oil Utilization Potential
Kinetics and selected variables (temperature, particle size and time) for extraction of Terminalia Catappa L Kernel Oil (TCKO) were investigated using solvent extraction. Kinetic models studied were: parabolic diffusion, power law, hyperbolic, Elovich and pseudo-second-order. In ascending order, the best-fitted models at the optimum temperature and oil yield were Elovich’s model, hyperbolic...
متن کاملOptimal Estimation of Weibull Distribution Parameters in order to Provide Preventive-Corrective Maintenance Program for Power Transformers
In this paper, a new method for modelling and estimation of reliability parameters of power transformer components in distribution and transmission voltage levels for preventive-corrective maintenance schedule of transformers is proposed. In this method, with optimal estimation of Weibull distribution parameters using least squares method and input data uncertainty reduction, failure rate and p...
متن کاملPower Auto-transformer Mechanical Faults Diagnosis Using Finite Element based FRA
Frequency response analysis (FRA) is a sensitive method established for testing the mechanical integrity of transformers. However, interpretation of FRA signature still needs expert opinions and there is no FRA interpretation code generally accepted. Various mechanical faults with different extents on power transformers are required to aid FRA interpretation. To address this challenge, in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016