Coil Combination Method for Multiple-Echo Sequences and PSF Mapping
نویسندگان
چکیده
INTRODUCTION: Phased array coils are increasingly used in MRI for improving the signal-to-noise ratio (SNR) or accelerating MRI acquisitions. Most image reconstruction approaches require a separate step to combine the data from the individual channels into a single composite image. Sum-ofsquares technique is widely used, but it is unsuitable when the phase information needs to be preserved. Optimal combination approaches like phase alignment [3] or SENSE [4] have been proposed, which require additional calibration data. Adaptive reconstruction by Walsh et al.[1] offers several advantages over both sum-of-squares and calibration data based methods, but is computation intensive and prone to errors for strongly T2*-weighted data due to the requirement of spatial smoothness of image phases. In this work a new method for coil combination is proposed, which is particularly suited for multi-echo, multi-reference or spectroscopic acquisitions, which intrinsically contain information on the temporal phase evolution. The performance of the method is demonstrated on the PSF mapping [4] application, widely used for distortion correction in EPI and BOLD fMRI in particular.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملDistortion Correction in EPI Using an Extended PSF Method with a Reversed Phase Gradient Approach
In echo-planar imaging (EPI), such as commonly used for functional MRI (fMRI) and diffusion-tensor imaging (DTI), compressed distortion is a more difficult challenge than local stretching as spatial information can be lost in strongly compressed areas. In addition, the effects are more severe at ultra-high field (UHF) such as 7T due to increased field inhomogeneity. To resolve this problem, two...
متن کاملEffect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence
Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملImage distortion correction in EPI: comparison of field mapping with point spread function mapping.
Echo-planar imaging (EPI) can provide rapid imaging by acquiring a complete k-space data set in a single acquisition. However, this approach suffers from distortion effects in geometry and intensity, resulting in poor image quality. The distortions, caused primarily by field inhomogeneities, lead to intensity loss and voxel shifts, the latter of which are particularly severe in the phase-encode...