Point-by-Point Radiofrequency Ablation Versus the Cryoballoon or a Novel Combined Approach: A Randomized Trial Comparing 3 Methods of Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation (The Cryo Versus RF Trial).

نویسندگان

  • Ross J Hunter
  • Victoria Baker
  • Malcolm C Finlay
  • Edward R Duncan
  • Matthew J Lovell
  • Muzahir H Tayebjee
  • Waqas Ullah
  • M Shoaib Siddiqui
  • Ailsa McLEAN
  • Laura Richmond
  • Claire Kirkby
  • Matthew R Ginks
  • Mehul Dhinoja
  • Simon Sporton
  • Mark J Earley
  • Richard J Schilling
چکیده

INTRODUCTION Catheter ablation of paroxysmal AF using the Cryoballoon (CRYO) has yielded similar success rates to conventional wide encirclement using radiofrequency catheter ablation (RFCA), but randomized data are lacking. Pilot data suggested a high success rate with a combined approach (COMBINED) using wide encirclement with RFCA followed by 2 CRYO applications to each vein. We compared these 3 strategies in a randomized controlled trial. METHODS AND RESULTS Patients undergoing first time paroxysmal AF ablation were randomized to RFCA, CRYO, or COMBINED. Patients were followed up at 3, 6, and 12 months with 7 days of ambulatory ECG monitoring. Success was defined as freedom from arrhythmia without antiarrhythmic drugs after a single procedure. A total of 237 patients were randomized. Success at 1 year was achieved in 47% in the RFCA group, 67% in the CRYO group, and 76% in the COMBINED group (P < 0.001 for RFCA vs. CRYO, P<0.001 for RFCA vs. COMBINED, and P = 0.220 for CRYO vs. COMBINED). Procedure time was 211 (IQR 174-256) minutes for RFCA compared to 167 (136-202) minutes for CRYO and 278 (243-327) minutes for COMBINED (P < 0.001 for RFCA vs. COMBINED, RFCA vs. CRYO, and CRYO vs. COMBINED groups). CONCLUSIONS Pulmonary vein isolation for paroxysmal AF is faster with CRYO and results in a higher single procedure success rate than conventional point by point RFCA. The COMBINED approach was not superior to CRYO alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation

Catheter ablation (CA) is an accepted treatment option for symptomatic atrial fibrillation (AF). Historically, CA has been performed with a point-by-point technique, using standard focal radiofrequency catheters and 3-dimensional (3D) navigation systems, with a procedural end point of electric pulmonary vein isolation (PVI). However, this CA approach requires advanced training and operator skil...

متن کامل

Cryoballoon Versus Open Irrigated Radiofrequency Ablation in Patients With Paroxysmal Atrial Fibrillation: The Prospective, Randomized, Controlled, Noninferiority FreezeAF Study.

BACKGROUND There is a lack of data on the comparative efficacy and procedural safety of open irrigated radiofrequency (RF) and cryoballoon catheter (CB) ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation. METHODS AND RESULTS In a prospective, noninferiority study, 315 patients were randomly assigned to RF (n=159) or CB (n=156) ablation. The primary end point...

متن کامل

Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation: A Multinational Multicenter Randomized Clinical Trial.

BACKGROUND Single-shot ablation techniques may facilitate safe and simple pulmonary vein isolation to treat paroxysmal atrial fibrillation. Multielectrode pulmonary vein isolation versus single tip wide area catheter ablation-paroxysmal atrial fibrillation is the first multinational, multicenter, prospective, noninferiority randomized clinical trial comparing multielectrode-phased radiofrequenc...

متن کامل

Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation.

BACKGROUND Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior t...

متن کامل

Cryoballoon ablation for atrial fibrillation

2014 Pulmonary vein (PV) isolation is the cornerstone of ablation therapy for atrial fibrillation. The majority of procedures are still performed using radiofrequency (RF) energy and a point-by-point ablation approach. Novel ‘single shot’ ablation tools with the aim of creating a circumferential lesion around the PVs with a single or a limited number of energy applications emerge. The currently...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 26 12  شماره 

صفحات  -

تاریخ انتشار 2015