Persistent topology for cryo-EM data analysis.

نویسندگان

  • Kelin Xia
  • Guo-Wei Wei
چکیده

In this work, we introduce persistent homology for the analysis of cryo-electron microscopy (cryo-EM) density maps. We identify the topological fingerprint or topological signature of noise, which is widespread in cryo-EM data. For low signal-to-noise ratio (SNR) volumetric data, intrinsic topological features of biomolecular structures are indistinguishable from noise. To remove noise, we employ geometric flows that are found to preserve the intrinsic topological fingerprints of cryo-EM structures and diminish the topological signature of noise. In particular, persistent homology enables us to visualize the gradual separation of the topological fingerprints of cryo-EM structures from those of noise during the denoising process, which gives rise to a practical procedure for prescribing a noise threshold to extract cryo-EM structure information from noise contaminated data after certain iterations of the geometric flow equation. To further demonstrate the utility of persistent homology for cryo-EM data analysis, we consider a microtubule intermediate structure Electron Microscopy Data (EMD 1129). Three helix models, an alpha-tubulin monomer model, an alpha-tubulin and beta-tubulin model, and an alpha-tubulin and beta-tubulin dimer model, are constructed to fit the cryo-EM data. The least square fitting leads to similarly high correlation coefficients, which indicates that structure determination via optimization is an ill-posed inverse problem. However, these models have dramatically different topological fingerprints. Especially, linkages or connectivities that discriminate one model from another, play little role in the traditional density fitting or optimization but are very sensitive and crucial to topological fingerprints. The intrinsic topological features of the microtubule data are identified after topological denoising. By a comparison of the topological fingerprints of the original data and those of three models, we found that the third model is topologically favored. The present work offers persistent homology based new strategies for topological denoising and for resolving ill-posed inverse problems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical Approaches to Improve Accuracy in Solving the Protein Topology Problem.

To take advantage of recent advances in genomics and proteomics it is critical that the three-dimensional physical structure of biological macromolecules be determined. Cryo-Electron Microscopy (cryo-EM) is a promising and improving method for obtaining this data, however resolution is often not sufficient to directly determine the atomic scale structure. Despite this, information for secondary...

متن کامل

Unsupervised Cryo-EM Data Clustering through Adaptively Constrained K-Means Algorithm

In single-particle cryo-electron microscopy (cryo-EM), K-means clustering algorithm is widely used in unsupervised 2D classification of projection images of biological macromolecules. 3D ab initio reconstruction requires accurate unsupervised classification in order to separate molecular projections of distinct orientations. Due to background noise in single-particle images and uncertainty of m...

متن کامل

DeepPicker: a Deep Learning Approach for Fully Automated Particle Picking in Cryo-EM

Particle picking is a time-consuming step in single-particle analysis and often requires significant interventions from users, which has become a bottleneck for future automated electron cryo-microscopy (cryo-EM). Here we report a deep learning framework, called DeepPicker, to address this problem and fill the current gaps toward a fully automated cryo-EM pipeline. DeepPicker employs a novel cr...

متن کامل

Fusion to a homo-oligomeric scaffold allows cryo-EM analysis of a small protein

Recent technical advances have revolutionized the field of cryo-electron microscopy (cryo-EM). However, most monomeric proteins remain too small (<100 kDa) for cryo-EM analysis. To overcome this limitation, we explored a strategy whereby a monomeric target protein is genetically fused to a homo-oligomeric scaffold protein and the junction optimized to allow the target to adopt the scaffold symm...

متن کامل

Artifact Correction for Zernike Phase-Plate Cryo-Electron Tomography

In cryo-electron microscopy (cryo-EM), vitreously frozen biological specimens can tolerate only a limited electron dose for imaging. Therefore, cryo-EM micrographs display weak contrast and a poor signal-to-noise ratio. This limits data interpretability and prevents efficient application of cryo-EM to a wider range of biological problems. Continued efforts have been invested in imaging methods ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal for numerical methods in biomedical engineering

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 2015