Bridging cardiovascular physics, physiology, and clinical practice: Karel H. Wesseling, pioneer of continuous noninvasive hemodynamic monitoring

نویسندگان

  • Berend E. Westerhof
  • Jos J. Settels
  • Willem-Jan W. Bos
  • Nico Westerhof
  • John M. Karemaker
  • Wouter Wieling
  • Gert A. van Montfrans
  • Johannes J. van Lieshout
چکیده

Berend E. Westerhof, Jos J. Settels, Willem-Jan W. Bos, Nico Westerhof, John M. Karemaker, Wouter Wieling, Gert A. van Montfrans, and Johannes J. van Lieshout Edwards Lifesciences BMEYE, Amsterdam, The Netherlands; Laboratory for Clinical Cardiovascular Physiology, Heart Failure Research Center, Academic Medical Center, Amsterdam, The Netherlands; Department of Internal Medicine, Sint Antonius Ziekenhuis, Nieuwegein, The Netherlands; Laboratory for Physiology, Institute for Cardiovascular Research, Vrije Universiteit, Amsterdam, The Netherlands; Department of Systems Physiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands; Department of Internal Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands; Department of Vascular Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands; and Medical Research Council/Arthritis Research United Kingdom, Centre for Musculoskeletal Ageing Research, School of Life Sciences, The Medical School, Queen’s Medical Centre, University of Nottingham, Nottingham, United Kingdom

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis.

We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a peripheral arterial blood pressure (ABP) waveform in humans. We specifically tested the mathematical analysis technique based on existing invasive and noninvasive hemodynamic data sets. With the former data set, we compared the app...

متن کامل

Continuous noninvasive hemodynamic monitoring in decompensated heart failure.

BACKGROUND The clinical and hemodynamic assessment at the bedside and the use of pulmonary artery catheter for the estimation of hemodynamic data have been used in decompensated heart failure. However, there are no data on the use of continuous noninvasive hemodynamic monitoring. OBJECTIVE To compare the data obtained through noninvasive hemodynamic monitoring with invasive ones in patients w...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

Characterizing the continuously acquired cardiovascular time series during hemodialysis, using median hybrid filter preprocessing noise reduction

The clinical characterization of cardiovascular dynamics during hemodialysis (HD) has important pathophysiological implications in terms of diagnostic, cardiovascular risk assessment, and treatment efficacy perspectives. Currently the diagnosis of significant intradialytic systolic blood pressure (SBP) changes among HD patients is imprecise and opportunistic, reliant upon the presence of hypote...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 308  شماره 

صفحات  -

تاریخ انتشار 2015