Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT.
نویسندگان
چکیده
UNLABELLED Respiratory motion can induce artifacts in cardiac PET/CT because of the misregistration of the CT attenuation map and emission data. Some solutions to the respiratory motion problem use 4-dimensional CT, but this increases patient radiation exposure. Realignment of 3-dimensional CT and PET images can remove apparent uptake defects caused by mispositioning of the PET emission data into the lung regions on the CT scan. This realignment is typically done as part of regular clinical quality assurance. We evaluated a method to improve on this standard approach, without increasing the radiation exposure to the patient, by acquiring a respiration-gated PET scan and separately aligning the 3-dimensional CT scan to each phase of the PET study. METHODS Three hundred ten clinical PET perfusion scans ((82)Rb [n = 187] and (13)N-ammonia [n = 123]) were retrospectively assessed. Studies were respiration-gated, and motion was measured between inspiration and expiration phases. Those studies with motion > or = 8 mm were evaluated for significant differences between inspiration and expiration. Studies with significant differences were reprocessed with the phase-alignment approach. The observed motion with (82)Rb and (13)N-ammonia for rest and stress imaging was also compared. RESULTS Twenty-three scans (7.41%) had motion > or = 8 mm, and 9 of these had significant differences between inspiration and expiration, suggesting the presence of respiratory artifacts. Phase-aligned respiratory motion compensation reduced this difference in 8 of 9 cases (89%). No significant differences were observed between (82)Rb and (13)N-ammonia, and motion during stress imaging was correlated with motion at rest (r = 0.61, P < 0.001). CONCLUSION Phase-aligned correction improves the consistency of PET/CT perfusion images by reducing discrepancies caused by respiratory motion. This new approach to CT-based attenuation correction has no additional patient radiation exposure and may improve the specificity of PET perfusion imaging.
منابع مشابه
Advanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملComparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging
AIM Respiratory motion affects cardiac PET-computed tomography (CT) imaging by reducing attenuation correction (AC) accuracy and by introducing blur. The aim of this study was to compare three approaches for reducing motion-induced AC errors and evaluate the inclusion of respiratory motion correction. MATERIALS AND METHODS AC with a helical CT was compared with averaged cine and gated cine CT...
متن کامل123I-metaiodobenzylguanidine imaging in the era of implantable cardioverter defibrillators: beyond ejection fraction.
1174 Correlation Between Glycolytic Phenotype and Tumor Grade in Soft-Tissue Sarcomas by F-FDG PET Matthias R. Benz, Sarah M. Dry, Fritz C. Eilber, Martin S. Allen-Auerbach, William D. Tap, David Elashoff, Michael E. Phelps, and Johannes Czernin 1182 Single-Phase CT Aligned to Gated PET for Respiratory Motion Correction in Cardiac PET/CT R. Glenn Wells, Terrence D. Ruddy, Rob A. DeKemp, Jean N....
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...