PET camera performance design evaluation for BGO and BaF2 scintillators (non-time-of-flight).

نویسنده

  • W H Wong
چکیده

Bismuth germanate (BGO) and barium fluoride (BaF2) scintillators are presently used in positron emission tomegraphy (PET) cameras. This study evaluates the important PET performance parameters of image resolution, true sensitivity, scatter background, accidental background, and realistic maximum radioactivity in the field of view for both BGO and BaF2 in an identical non-time-of-flight, whole-body camera configuration. These performance parameters are evaluated for three phantoms simulating (a) the head, (b) whole-body cross-section and (c) heart/kidney. This study finds that the high stopping power of BGO yields higher sensitivity, higher resolution, less vignetting, better immunity from scattered gamma, and lower accident/true ratio at any dose level. The faster BaF2 timing acceptance window is traded off by its vulnerability to noncoincidental scatter-gamma which increases accidental coincidences. The BGO is found to be a better choice for non-time-of-flight systems especially with large objects which produce a lot of noncoincidental scatter-gammas. This study also found that the practical diminishing return maximum activity within the field-of-view is approximately 20-25 mCi for existing conventional cameras.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.

UNLABELLED The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan...

متن کامل

BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce...

متن کامل

Time of Flight in PET Revisited

PET scanners based on LSO have the potential for significantly better coincidence timing resolution than the 6 ns FWHM typically achieved with BGO. This study analyzes the performance enhancements made possible by improved timing as a function of the coincidence time resolution. If 500 ps FWHM coincidence timing resolution can be achieved in a complete PET camera, the following four benefits ca...

متن کامل

Performance evaluation of two SiPMs arrays coupled to pixelated scintillations for PET/MR applications

Technological Educational Institute of Athens, Athens, Greece The purpose of this study is to investigate the behavior of the new generation of SensL SiPM arrays, ArrayB and ArrayM, for PET/MR applications. The evaluation of the SiPMs performance underwent with pixelated GaGG and BGO scintillators with 2×2×5 mm pixel size and various coupling schemes for 511keV and 662keV energies. To acquire r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 1988