Polyethylene Glycol-Based Synthetic Hydrogel Sealant for Closing Vitrectomy Wounds: An In Vivo and Histological Study
نویسندگان
چکیده
PURPOSE We conducted an in vivo study using Dutch pigmented rabbit eyes to test the usefulness of polyethylene glycol (PEG) sealant for the closure of sutureless sclerotomies in microincisional vitrectomy surgery (MIVS). METHODS Three-port, 23-gauge vitrectomy was performed on rabbit eyes. After air leakage was confirmed by the application of 0.625% povidone-iodine at the sclerotomy site, PEG sealant was subconjunctivally injected using a 27-gauge needle through conjunctival incisions to cover the sclerotomy wounds, following which it was polymerized by the application of xenon light for 60 seconds. Ophthalmological examinations and intraocular pressure measurements were conducted the day before and 1, 3, 5, and 7 days after surgery. The eyes were enucleated for histological evaluation 7 days after surgery. RESULTS PEG sealant was rapidly polymerized by the application of xenon light after subconjunctival injection, and it firmly sealed the sclerotomies without air leakage, as confirmed by povidone-iodine dropping, in all cases. Conjunctival and scleral wounds closed with PEG sealant were successfully attached and remained intact till the end of the follow-up period. There was no sign of postoperative hypotony or infection in any eye, and no adverse effects of PEG sealant were found. In histological examination, linear scar formation and eosinophilic staining of collagen fibers were observed at the sclerotomy sites, while the sclerotomy tunnels appeared tightly closed. CONCLUSIONS PEG sealant can be useful for the closure of sutureless 23-gauge vitrectomy incisions in rabbits. TRANSLATIONAL RELEVANCE The PEG sealant may become an effective option for closing vitrectomy incisions including pediatric cases.
منابع مشابه
Polyethylene glycol hydrogel polymer sealant for vitrectomy surgery: an in vitro study of sutureless vitrectomy incision closure.
OBJECTIVE To test a novel hydrogel sealant to secure sutureless sclerotomies under variable intraocular pressure conditions. METHODS In cadaver eyes, 23- and 20-gauge (G) sclerotomies were constructed. Sixteen 23-G beveled sclerotomies were constructed in 4 eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were left bare. All sclerotomies were monitored for leaks while the ...
متن کاملPreliminary investigation of a polyethylene glycol hydrogel "nerve glue"
BACKGROUND Polyethylene glycol (PEG) hydrogel is a biocompatible semi-adherent gel like substance that can potentially augment nerve repair much like a fibrin sealant. Potential advantages of this substance include fast preparation and set up time, as well as adhesion inhibiting properties. The purpose of this study was to perform an initial evaluation of PEG hydrogel in this application. MET...
متن کاملDelayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with ...
متن کاملEvaluation of the neurotoxicity of the polyethylene glycol hydrogel dural sealant.
AIM Although polyethylene glycol (PEG) is a neutral, biocompatible hydrophilic polymer recognized for its lack of interaction with biological barrier, its neurotoxicity has not been clearly identified in neurosurgery. This study is constructed to evaluate the possible neurotoxicity of a PEG hydrogel dural sealant. MATERIAL AND METHODS After a burrhole was opened in the left pa...
متن کاملA Cost-benefit Analysis of Using Polyethylene Glycol Hydrogel Sealant versus Fibrin Glue as a Dural Sealant for Posterior Fossa Surgery in the United States
Background: Cerebrospinal fluid (CSF) leaks are a well-known complication of posterior fossa neurosurgery. The use of dural repair adjuncts has been associated with fewer CSF leaks and subsequently, lower medical costs. Objectives: To determine if the use of polyethylene glycol hydrogel sealant (DuraSeal dural sealant system [DuraSeal]), resulted in cost savings in the United States compared to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -