Dissection of Ascending Aorta After Aortic Valve Replacement and Reduction Aortoplasty.

نویسندگان

  • Maria Hashmi
  • Mudasser Iqbal Dar
  • Asad Ullah Khan
  • Farhan Khan
  • Abdul Bari Khan
چکیده

A case of Debakey type-II (Stanford type-A) dissecting aortic aneurysm, after aortic valve replacement and reduction aortoplasty, is reported. The patient was 35 years male who was diagnosed of severe aortic regurgitation along with aortic root dilatation of 7 cm. He underwent aortic valve replacement with 27-ASt Jude's mechanical aortic valve along with reduction aortoplasty. Nine months later, he was admitted to our hospital with complaint of severe sudden anterior chest pain. Computed tomography with aortic enhancement showed dilatation and dissection of ascending aorta. Successful operation of aortic root replacement with composite graft was performed and patient was discharged without any postoperative complication. The aortic diameter at the time of aortic valve replacement is an independent risk factor for the late aortic dissection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Mid-term results of aortoplasty for dilated ascending aorta associated with aortic valve disease.

BACKGROUND Dilatation of the ascending aorta concomitant with aortic valve disease is occasionally associated with progressive enlargement of the ascending aorta or acute aortic dissection (AAD). However, surgical procedure of choice for the aorta and its indication are controversial. PATIENTS AND METHODS From July 1995 to August 2001, 10 patients with a moderately dilated ascending aorta (me...

متن کامل

Successful use of reduction aortoplasty in patients undergoing aortic valve replacement with ascending aortic dilatation.

Results We identified 26 patients who underwent aortoplasty during aortic valve replacement. Age (66 ± 13 years), sex (male: female, 15:11), euroscore (5 ± 3), bypass time (95 ± 18 min), xclamp time (68 ± 13 min). Native valve pathology (stenosis: regurgitation: mixed, 13:4:9). Type of implant (mechanical: biological, 13:13). Median prosthetic valve size was 25 mm in all patients. Post-operativ...

متن کامل

Reduction aortoplasty with external wrapping associated with aortic valve replacement in high-risk patients.

OBJECTIVE To assess the midterm follow-up of reduction aortoplasty with external wrapping associated with aortic valve replacement in high risk patients. METHODS Six patients with ascending aortic aneurysm and aortic valve disease were included in this study. Four of them were male. The age ranged from 61 to 70 years (mean 65.7 years). One patient presented severe mitral valve insufficiency. ...

متن کامل

Safe wrapping of the borderline dilated ascending aorta during aortic valve replacement

BACKGROUND Techniques of reduction aortoplasty are widely published in the literature with conflicting results. External support seems to be an important factor in preventing recurrence but, in some cases, this technique caused erosion of the aorta because of the wrinkles the prosthesis creates in the rear side of the aorta. CASE PRESENTATION A 73 year old patient with aortic valve stenosis a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the College of Physicians and Surgeons--Pakistan : JCPSP

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 2015