Automated calmagite compleximetric measurement of magnesium in serum, with sequential addition of EDTA to eliminate endogenous interference.
نویسندگان
چکیده
We describe an automated method for magnesium assay, for use with the Cobas-Bio centrifugal analyzer. Magnesium is reacted with calmagite, a dye, and the absorbance of the magnesium-dye complex at 520 nm is measured. EDTA is then added to break up the complex and the absorbance at 520 nm is re-measured to correct for sample color and turbidity. Including ethylene glycol bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) and triethanolamine in the dye reagent eliminates interference by calcium and iron. Within-run CVs were less than 2.0% for concentrations of magnesium ranging from 18 to 40 mg/L, and less than 4% for a magnesium concentration of 9.4 mg/L. Day-to-day precision data, determined over five months were: mean = 21.0 mg/L, CV = 2.7%; mean = 43.0 mg/L, CV = 3.2% (n = 550 for both). Comparison of the Cobas-Bio method (y) with an atomic absorption spectrometric method (x) gave the following results: y = 0.968x + 0.448, r = 0.986, Sy/x = 0.34 mg/L, mean x = 19.8 mg/L, mean y = 19.6 mg/L, n = 44. Hemoglobin, bilirubin, and turbidity do not interfere. The standard curve is linear up to a magnesium concentration of 97 mg/L.
منابع مشابه
Micellar improvement of the calmagite compleximetric measurement of magnesium in plasma.
Magnesium in plasma is determined by diluting a 50-microL sample with 5.0 mL of stable calmagite reagent containing the amphoteric detergent Empigen BB, and buffered with 2-amino-2-methyl-1-propanol at pH 11.5. The calcium response is masked with strontium-buffered [ethylene-bis(oxyethylenenitrilo)]tetraacetate (EGTA), while iron is masked with triethanolamine. The detergent causes an increased...
متن کاملMeasurement of serum magnesium with a centrifugal analyzer.
We show how serum magnesium can be determined with a centrifugal analyzer. The method is based upon a manual procedure involving magnesium/calmagite complex formation in an alkaline reagent mixture. The assay, performed at 30 degrees C, requires 5 mul of serum in a final reaction volume of 405 mul, including 350 mul of reagent mixture. The stable color produced at 1 min is measured at 520 nm. L...
متن کاملSimultaneous Determination of Calcium and Magnesium of Serum by a Single Chelometric Titration.
Titration of a trichloracetic acid filtrate of serum with EDTA is carried out at pH 9.8 using an excess of Calmagite indicator. Successive photometric readings of percentage transmission, made with an EEL titrator, are plotted against the volume of EDTA added. There is very little change at first while calcium is being complexed; the reading then decreases rapidly while magnesium is being titra...
متن کاملInterference of medical contrast media on laboratory testing
The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iod...
متن کاملHighly Efficient In Vitro Production of Bovine Blastocyst in Cell-Free Sequential Synthetic Oviductal Fluid vs. TCM199 Vero Cell Co-Culture System
Background The aim of this study was to establish a cell-free sequential culture system that can support high levels of in vitro embryo development and blastocyst formation from bovine zygotes. To this end, this investigation was carried out to evaluate the effects of glucose, serum and EDTA on bovine zygote in vitro development. MaterialsAndMethods Bovine presumptive zygotes were derived from ...