Flow-injection analysis method for the determination of nitrite and nitrate in natural water samples using a chemiluminescence NOx monitor.

نویسندگان

  • Yukio Kanda
  • Masafumi Taira
چکیده

A flow-injection analysis method for the determination of nitrite and nitrate in natural water samples has been developed that consists of two systems based on their reduction to NO with hydrazine and/or ascorbic acid, followed by chemiluminescence detection. The procedure of sweeping the generated NO into an NOx monitor, by means of a gas-liquid separating coil consisting of microporous polytetrafluoroethylene (PTFE) tubing, offers practical advantages. The adjustment of the carrier gas-flow rates could yield the same calibration graphs for the two measurement systems, and the accumulation sweeping mode provides a higher sensitivity. Chemiluminescence detection allows a wide linear calibration range of 5 x 10(-8) to 5 x 10(-5) M. The detection limits for nitrate and nitrite, defined as three-times the standard deviation of measurement blanks, are 2 x 10(-8) M and 1 x 10(-8) M, respectively, and the average precision was 3.2% at ambient natural concentration levels. Recovery tests were between 94% and 106% for a variety of natural water samples. The method is relatively free from interferences from the substances normally found in natural water, and only ferric ion has an effect for the nitrite determination.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 – 1000 μg N L (R = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 μg N L and relative standard deviatio...

متن کامل

Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples.

A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxyb...

متن کامل

Investigation of Nitrate and Nitrite Concentration in Drinking Water of some Universities of Iran

Introduction: Water is vital for life. Its inadequate quality causes significant effects on the health condition of the individuals and society. Groundwater is one of the sources of Nitrate that level over standard limits may lead to several health problems such as hemoglobin metabolism and the formation of nitro amino compounds. Therefore, the aim of this study is determining ...

متن کامل

Rapid method for simultaneous determination of nitrite and nitrate in water samples using short-column ion-pair chromatographic separation, photochemical reaction, and chemiluminescence detection.

A rapid method has been developed for the simultaneous determination of nitrite and nitrate. The separation of nitrite and nitrate was achieved using an octadecylsilane (ODS) short column (5 µm, 20 × 4.6 mm) with 10 mM of borate buffer-methanol (99.5:0.5, v/v; pH 10.0), containing 5 mM of lauryltrimethylammonium chloride and 50 mM of NaBr. These ions were detected by luminol chemiluminescence f...

متن کامل

L-Arginine Supplementation Influenced Nitrite but Not Nitrate and Total Nitrite in Rabbit Model of Hypercholesterolemia

Background: The assessment of altered nitric oxide (NO) availability is of potentially important diagnostic and prognostic significance. The present study is aimed to investigate the effect of L-arginine (as a natural NO donor) supplementation on NO metabolite in a rabbit model of hypercholesterolemia to find a reliable marker for endothelial NO production. Methods: White male rabbits (n = 30)...