Evaluation of use of the optional unit QA-810V for the determination of five-part leukocyte differentials

نویسندگان

  • Izumi Tsuda
  • Takayuki Takubo
  • Tomio Kamitani
  • Noriyuki Tatsumi
چکیده

The newly developed QA-810V is an optional unit for the determination of five-part white blood cell differentials. It can be used together with the same manufacturer's haematology analyser which has been used in relatively small-sized laboratories. The present study evaluates the basic performance of the QA-810 V and the MEK-8118 haematology analyser using routinely obtained blood specimens treated with ethylenedioaminetetraacetic acid-2K. In this evaluation, reproducibility was good and little carryover was found. Accurate measurements were possible for up to 24h of storage. Storage at 4 degrees C yielded more stable measurements of complete blood counts and five-part differentials than storage at room temperature. A good correlation between findings with the MEK-8118 haematology analyser and those with the SE-9000 haematology analyser was found for complete blood counts. The leukocyte differential obtained with the QA-810 V correlated well with eye counts, with r > 0.9 for percentages of neutrophils, lymphocytes and eosinophils. Scattergrams obtained with the QA-810 V reflected the presence of abnormal cells. The performance of the QA-810 V was excellent and it can improve the quality of testing in clinical laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Statistical Model for Evaluation Interactive Question Answering Systems Using Regression

The development of computer systems and extensive use of information technology in the everyday life of people have just made it more and more important for them to make quick access to information that has received great importance. Increasing the volume of information makes it difficult to manage or control. Thus, some instruments need to be provided to use this information. The QA system is ...

متن کامل

Evaluation of Leukoreduction in Packed Cell Units Filtered by Home-Made Bedside Filters: Pre and Post Revision of Product Technology and Materials According to Standard Values

Introduction: Leukocytes causing a wide variety of side effects after transfusion are present in all blood products prepared by standard methods. As a consequence, the use of filter technology for leukoreduction has been widely practiced .According to AABB accreditation in 1996, leukoreduced blood components must contain less than 5×106 leukocytes per unit, but sometimes this value is higher ev...

متن کامل

Comparison between two different methods used for IMRT plans QA of Prostate cancer

Introduction: The aim of this study is evaluation of two Quality Assurance methods in sliding window IMRT technique and Determination of gamma index in both methods   Materials and Methods: In this study two tools named" Delta4" phantom and " Epiqa" software has been used to perform QA on the treatment plan before the actual treatment by Varian linear acceler...

متن کامل

Performance evaluation and availability analysis of ammonia synthesis unit in a fertilizer plant

This paper discusses the performance evaluation and availability analysis of ammonia synthesis unit of a fertilizer plant. The fertilizer plant is a complex and repairable engineering system comprises of various units viz. shell gasification and carbon recovery, desulphurization, co-shift conversion, decarbonation, nitrogen wash and ammonia synthesis etc. One of the most important functionaries...

متن کامل

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2001