Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: application to a bioequivalence study.

نویسندگان

  • A A Almeida
  • D R Campos
  • G Bernasconi
  • S Calafatti
  • F A P Barros
  • M N Eberlin
  • E C Meurer
  • E G Paris
  • J Pedrazzoli
چکیده

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of memantine (I) in human plasma is presented. Sample preparation consisted of the addition of amantadine (II) as internal standard (IS), liquid-liquid extraction in basic conditions using a mixture of diethyl ether-chloroform (7:3, v/v) as extracting solvent, followed by centrifugation, solvent evaporation and sample reconstitution in methanol. Both I and II (internal standard) were analyzed using a C18 column and a mobile phase composed of methanol-water-formic acid (80:20:0.1, v/v/v). Eluted compounds were monitored using positive mode electrospray (ES) tandem mass spectrometry. The analyses were carried out by selected reaction monitoring (SRM) using the parent to daughter combinations of m/z 180>163 (memantine) and m/z 152>135 (amantadine). The peak areas from the analyte and IS were used for quantification of I. The achieved limit of quantification (LOQ) was 0.1 ng/mL; the assay exhibited a linear dynamic range of 0.1-50.0 ng/mL with a determination coefficient (r2) of at least 0.98. Validation results on linearity, specificity, accuracy, precision and stability, as well as on application to the analysis of samples taken up to 320 h after oral administration of 20mg (two 10mg capsules) of I in healthy volunteers demonstrated the applicability to bioequivalence studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Development and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma

     A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 848 2  شماره 

صفحات  -

تاریخ انتشار 2007