Do we need bispectral index monitoring during total intravenous anesthesia for lumbar discectomies?

نویسندگان

  • Didem Tuba Akçali
  • Zerrin Ozköse
  • Sahin Yardim
چکیده

The aim of this study was to investigate the effect of bispectral index (BIS) monitoring on hemodynamic parameters, drug consumption and awareness during total intravenous anesthesia (TIVA) with remifentanil and propofol in lumbar discectomies. After institutional ethical committee approval, ASAI-II 56 patients were divided as control and BIS groups. Anesthesia was induced by bolus remifentanil 1 mug/kg in both groups; propofol 2 mg/kg in was used in the control group while propofol was titrated to BIS 45- 65 values in the BIS group. Anesthesia was maintained by remifentanil and propofol infusions. Drug consumption, time to extubation and awareness were recorded. Demographic parameters were similar between the groups. Consumption of propofol was lower, and time to extubation was shorter in the BIS group; there was no difference between awareness among groups. BIS monitoring was helpful for propofol titration and decreased propofol consumption, but not enough to prevent reaction to noxious stimuli. Standard anesthesia titration considering hemodynamic parameters was enough for most ASA I-II patients for lumbar discectomies. BIS might be more helpful for patients who cannot show hemodynamic responses to noxious stimuli. More studies are needed to investigate the correlation between positioning and awareness using BIS monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

Changes in bispectral index values during lumbar arthrodesis.

EDITOR: Several authors have reported sudden increases of the bispectral index values during different procedures such as endoscopic shoulder surgery [1], deep hypothermic circulatory arrest [2] or after using an upper-body blanket for warming [3]. In addition, spurious bispectral index values can be observed when the electromyogram activity of the bispectral index monitor reaches a value of 50...

متن کامل

The EC90 of remifentanil for blunting cardiovascular responses to head fixation for neurosurgery under total intravenous anesthesia with propofol and remifentanil based on bispectral index monitoring: estimation with the biased coin up-and-down sequential method

BACKGROUND Head fixation can induce hemodynamic instability. Remifentanil is commonly used with propofol for total intravenous anesthesia (TIVA) during neurosurgery. This study investigated the 90% effective concentration (EC90) of remifentanil for blunting of cardiovascular responses to head fixation during neurosurgery via bispectral index (BIS) monitoring. METHODS Fifty patients undergoing...

متن کامل

The assessment of memory under total intravenous anesthesia.

BACKGROUND AND OBJECTIVES In this study, we aimed to assess implicit and explicit memory in patients who had abdominal surgery under total intravenous anesthesia (TIVA) with propofol and remifentanil, in which anesthesia level was controlled by bispectral index (BIS) monitoring. METHOD Total intravenous anesthesia was administered to 60 adult patients, to obtain BIS levels of 40-60. Patients ...

متن کامل

Inappropriate elevation of bispectral index values in robot assisted thyroidectomy with electromyographic endotracheal tube -A case report-

We report a case of an erroneously elevated bispectral index (BIS) during robot assisted thyroidectomy using an electromyographic endotracheal tube (EMG tube), which is safe and useful for laryngeal electromyographic monitoring. Ten minutes after start of the operation, a sudden increase of BIS value up to 98 was noticed. The BIS values were not decreased to < 65 with supplemental anesthetics. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2008