Calibration of BAS-TR image plate response to high energy (3-300 MeV) carbon ions.

نویسندگان

  • D Doria
  • S Kar
  • H Ahmed
  • A Alejo
  • J Fernandez
  • M Cerchez
  • R J Gray
  • F Hanton
  • D A MacLellan
  • P McKenna
  • Z Najmudin
  • D Neely
  • L Romagnani
  • J A Ruiz
  • G Sarri
  • C Scullion
  • M Streeter
  • M Swantusch
  • O Willi
  • M Zepf
  • M Borghesi
چکیده

The paper presents the calibration of Fuji BAS-TR image plate (IP) response to high energy carbon ions of different charge states by employing an intense laser-driven ion source, which allowed access to carbon energies up to 270 MeV. The calibration method consists of employing a Thomson parabola spectrometer to separate and spectrally resolve different ion species, and a slotted CR-39 solid state detector overlayed onto an image plate for an absolute calibration of the IP signal. An empirical response function was obtained which can be reasonably extrapolated to higher ion energies. The experimental data also show that the IP response is independent of ion charge states.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Pressure effects on ion Acceleration on the GEMINI laser

We report on the absolute calibration of amicro channel plate (MCP) detector, installed asdetector in a Thomson parabola spectrometer. Thecalibration delivers the relation between a registeredcount numbers in the CCD camera (on which the MCPphosphor screen is imaged) as a result of the impact ofan ion beam onto the MCP. The particle response ofthe whole detection...

متن کامل

Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

متن کامل

First results of carbon ion track structure imaging in low pressure gas

The relative biological effectiveness (RBE) is an important parameter in heavy ion treatment planning. It is well known that the RBE does not only depend on the LET of a particle, but also on the ion sort.. This can be explained by the difference in the local ionisation distribution for different kind of ions, expressed by LET and radial ionisation distribution. Our goal is to measure these par...

متن کامل

An approximate analytical solution of the Bethe equation for charged particles in the range of radiotherapy energy

Charged particles such as protons and carbon ions are an increasing tool in radiation therapy. However, unresolved physical problems prevent optimal performance, including estimating the deposited dose in non-homogeneous tissue, is an essential aspect of optimizing treatment. The Monte Carlo (MC) method can be used to estimate the amount of radiation, but, this powerful computing operation is v...

متن کامل

Ionization defect for alpha particles in various gases

The ionization produced by the Li7* and o<-particles from the reaction BlO(njo<)Li7* as they were stopped in argonj argon-nitrogen~ and argoncarbon dioxide gas mixtures was measured. A gridded parallel-plate ionization chamber employing electron collection was used. Plutonium alpha particles were used for calibration and the ionization electron pulses were amplified and sorted-with an electroni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 86 12  شماره 

صفحات  -

تاریخ انتشار 2015