Left ventricular volume and ejection fraction assessment with transoesophageal echocardiography: 2D vs 3D imaging.

نویسندگان

  • B Cowie
  • R Kluger
  • M Kalpokas
چکیده

BACKGROUND Developments in transducer technology have enabled the use of three-dimensional transoesophageal echocardiography (3D TOE) in the operating theatre. Transthoracic echocardiography (TTE) 3D left ventricular (LV) volumes and ejection fraction (EF) agree better with magnetic resonance imaging (MRI) measurements, with less intra- and inter-observer variability compared with 2D. This has not been validated with 3D TOE. The aim of this study was to assess the bias, limits of agreement, and reproducibility of 3D TOE and 2D TOE LV volumes and EF in cardiac surgical patients. METHODS Sixty-three patients having cardiac surgery with TOE were evaluated. LV volumes and EF were calculated using modified Simpson's method on 2D mid-oesophageal four- and two-chamber views, xPlane, and from a 3D full-volume data set. Intra- and inter-observer variability were assessed in a subset of 17 patients. RESULTS Real-time 3D TOE volume and EF assessment was possible in 59 of the 63 patients. Median end-diastolic volumes (EDVs) as measured by 2D, xPlane, and 3D techniques were 98.5, 94, and 97 ml. Median ESVs were 38.5, 40 and 35.6 ml. Median EFs were 58, 54 and 62.2%. There were no significant pairwise differences between these measurements. The limits of agreement for all comparisons were wide, and there were no statistically significant differences between the three methods in intra- or inter-observer variability. CONCLUSION The intraoperative use of 3D TOE to estimate LV volumes and EF has small bias compared with 2D assessments, wide limits of agreement, and no clear advantages compared with standard 2D TOE imaging in terms of LV volume and EF assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left Ventricular Ejection Fraction and Volumes: It Depends on the Imaging Method

BACKGROUND AND METHODS In order to provide guidance for using measurements of left ventricular (LV) volume and ejection fraction (LVEF) from different echocardiographic methods a PubMed review was performed on studies that reported reference values in normal populations for two-dimensional (2D ECHO) and three-dimensional (3D ECHO) echocardiography, nuclear imaging, cardiac computed tomography, ...

متن کامل

Assessment of left ventricular systolic function by deformation imaging derived from speckle tracking: a comparison between 2D and 3D echo modalities.

AIMS Deformation imaging is undergoing continuous development with the emergence of new technologies allowing the evaluation of the different components of strain simultaneously in three dimensions. Assessment of all global strain parameters in 2D and 3D modes and comparison with LVEF have been the focus of our study. METHODS AND RESULTS Out of 166 patients, 147 were evaluated with the use of...

متن کامل

Quantitative assessment of primary mitral regurgitation using left ventricular volumes: a three-dimensional transthoracic echocardiographic pilot study.

AIMS To investigate the value of assessment of mitral regurgitant fraction (RF) using left ventricular (LV) volumes obtained by three-dimensional echocardiography (3DE) to quantify primary mitral regurgitation (MR). METHODS AND RESULTS Sixty patients with primary MR in sinus rhythm were prospectively enrolled. RF was calculated using either 2DE or 3DE LV volumes obtained as follows: (LV total...

متن کامل

Three-dimensional echocardiographic analysis of left ventricular function during hemodialysis.

BACKGROUND The effects of hemodialysis (HD) on left ventricular (LV) function have been studied by various echocardiographic techniques (M-mode, 2D echocardiography). These studies are hampered by a low accuracy of measurements because of geometric assumptions regarding LV shape. Three-dimensional echocardiography (3DE) overcomes this limitation. METHODS We tested the feasibility of 3DE asses...

متن کامل

Current Status of 3-Dimensional Speckle Tracking Echocardiography: A Review from Our Experiences

Cardiac function analysis is the main focus of echocardiography. Left ventricular ejection fraction (LVEF) has been the clinical standard, however, LVEF is not enough to investigate myocardial function. For the last decade, speckle tracking echocardiography (STE) has been the novel clinical tool for regional and global myocardial function analysis. However, 2-dimensional imaging methods have li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 110 2  شماره 

صفحات  -

تاریخ انتشار 2013