Dialyzer reuse with peracetic acid does not impact patient mortality.

نویسندگان

  • T Christopher Bond
  • Allen R Nissenson
  • Mahesh Krishnan
  • Steven M Wilson
  • Tracy Mayne
چکیده

BACKGROUND AND OBJECTIVES Numerous studies have shown the overall benefits of dialysis filter reuse, including superior biocompatibility and decreased nonbiodegradable medical waste generation, without increased risk of mortality. A recent study reported that dialyzer reprocessing was associated with decreased patient survival; however, it did not control for sources of potential confounding. We sought to determine the effect of dialyzer reprocessing with peracetic acid on patient mortality using contemporary outcomes data and rigorous analytical techniques. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS We conducted a series of analyses of hemodialysis patients examining the effects of reuse on mortality using three techniques to control for potential confounding: instrumental variables, propensity-score matching, and time-dependent survival analysis. RESULTS In the instrumental variables analysis, patients at high reuse centers had 16.2 versus 15.9 deaths/100 patient-years in nonreuse centers. In the propensity-score matched analysis, patients with reuse had a lower death rate per 100 patient-years than those without reuse (15.2 versus 15.5). The risk ratios for the time-dependent survival analyses were 0.993 (per percent of sessions with reuse) and 0.995 (per unit of last reuse), respectively. Over the study period, 13.8 million dialyzers were saved, representing 10,000 metric tons of medical waste. CONCLUSIONS Despite the large sample size, powered to detect miniscule effects, neither the instrumental variables nor propensity-matched analyses were statistically significant. The time-dependent survival analysis showed a protective effect of reuse. These data are consistent with the preponderance of evidence showing reuse limits medical waste generation without negatively affecting clinical outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dialyzer reuse and mortality risk in patients with end-stage renal disease: a systematic review.

BACKGROUND AND AIM Robust evidence about dialyzer reuse effects on mortality is not available. Our aim was to summarize the evidence for the effectiveness of dialyzer reuse compared to single use in patients with end-stage renal disease. METHODS We searched MEDLINE, Embase, CINAHL, SciELO, LILACS, USRDS ADR, universities' theses databases and annals of congress from major nephrology societies...

متن کامل

Abandoning peracetic acid-based dialyzer reuse is associated with improved survival.

BACKGROUND AND OBJECTIVES Higher mortality risk reported with reuse versus single use of dialyzers is potentially related to reuse reagents that modify membrane surface characteristics and the blood-membrane interface. A key mechanism may involve stimulation of an inflammatory response. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS In a prospective crossover design, laboratory markers and mor...

متن کامل

Effects of disinfectants in renal dialysis patients.

Patients receiving hemodialysis therapy risk exposure to both disinfectants and sterilants. Dialysis equipment is disinfected periodically with strong solutions of hypochlorite or formaldehyde. More recently, reuse of dialyzers has introduced the use of additional sterilants, such as hydrogen peroxide and peracetic acid. The use of these sterilants is recognized by the center staffs and the hom...

متن کامل

A quality and cost-benefit analysis of dialyzer reuse in hemodialysis patients.

BACKGROUND To evaluate the benefits of dialyzer reuse for hemodialysis (HD) patients, including the cost of HD treatment and patient's survival, a comparison was made regarding the standard practice of single-use dialysis. METHODS From January 1, 2005, to December 31, 2005, a total of 128,232 successive HD treatments in 822 patients in Chang Gung Memorial Hospital-Kaohsiung Medical Center wer...

متن کامل

Delayed Dialyzer Reprocessing for Home Hemodialysis.

Although dialyzer reuse for home hemodialysis (done by patients at home) has been in practice since the 1960s, it is now almost completely abandoned. The need for dialyzer reuse resurfaced with the renewed interest in daily/nightly forms of home hemodialysis and the associated increase in operating costs. We describe a method of dialyzer reuse based on reprocessing of dialyzers at the center, a...