HST/WFC3 In-Orbit Grism Performance

نویسندگان

  • H. Kuntschner
  • M. Kümmel
  • J. R. Walsh
چکیده

The Wide Field Camera 3 (WFC3) is fitted with three grisms for slitless spectroscopy. In the UVIS channel there is one grism, G280, for the near-UV to visible range (200 400nm; 1.4nm/pix). The IR channel has two grisms: G102 for the shorter (800-1150nm; 2.45nm/pix) and G141 for the longer (1100-1700nm; 4.65nm/pix) NIR wavelengths. Using SMOV and Cycle 17 calibration data taken on WR stars, planetary nebulae and flux standard stars, we have assessed the performance of the grisms. We have measured the field-dependent trace locations and dispersion solutions and determined the throughputs. The trace and wavelength solutions for the IR grisms were found to be linear functions, varying smoothly across the field-of-view. The UVIS grism exhibits a highly bent trace and significantly non-linear dispersion solutions. The maximum throughputs for the G102 and G141 grisms, including the telescope optics, are 41% at 1100 nm and 48% at 1450 nm, respectively. Limiting magnitudes at S/N=5 and a 1h exposure are JAB=22.6 and HAB=22.9 for the G102 and G141 grisms, respectively. The results are published as sensitivity and configuration files that can be used with the dedicated extraction software aXe to reduce WFC3 slitless data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hubble Space Telescope Wfc3 Grism Spectroscopy and Imaging of a Growing Compact Galaxy

We present HST/WFC3 grism spectroscopy of the brightest galaxy at z > 1.5 in the GOODS-South WFC3 Early Release Science grism pointing, covering the wavelength range 0.9μm – 1.7μm. The spectrum is of remarkable quality and shows the redshifted Balmer lines Hβ, Hγ, and Hδ in absorption at z = 1.902± 0.002, correcting previous erroneous redshift measurements from the rest-frame UV. The average re...

متن کامل

WFC3 SMOV Proposal 11451: The Photometric Performance and Calibration of WFC3/IR

We present the first on-orbit observations to characterize the photometric performance of the infrared (IR) camera on WFC3, based on data collected during the Servicing Mission Orbital Verification 4 Phase (SMOV4) shortly after the installation of the WFC3 instrument on HST. The photometric zero points and stability of the detector are measured in all 15 IR filters, using two different HST spec...

متن کامل

Calibration Status and Results for Wide Field Camera 3

Wide Field Camera 3 (WFC3) is a general-purpose imager in development for installation in HST Servicing Mission 4 (SM4). Covering the wavelength range of 200-1700 nm in two observing channels, WFC3 offers powerful new capabilities, particularly in the near-ultraviolet and near-infrared bands. During 2004, the instrument was integrated and underwent a substantial suite of end-to-end characteriza...

متن کامل

WFC3/UVIS Detectors: On-orbit Performance

WFC3 is a fourth-generation instrument installed on HST in May 2009. Designed as a panchromatic camera, it features both a UVIS and an IR channel, selectable via a channel select mechanism (CSM), allowing sequential imaging. Both detectors are performing well on-orbit and are now in standard science operations. This poster presents some of the UVIS detector highlights as well as remaining issue...

متن کامل

Evaluation of Selection Criteria for WFC3 Replacement IR Grisms

This report describes the rationale for recommending focus as the primary selection criterion in choosing the final IR replacement grisms. Introduction Instrument-level imaging during the first thermal vacuum ground test of the WFC3 IR channel in the fall of 2004 revealed that while the IR filters performed as expected, well within specification, the grisms produced significantly out-of-focus, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012