Spinal cord MRI in multiple sclerosis with multicoil arrays: a comparison between fast spin echo and fast FLAIR.
نویسندگان
چکیده
OBJECTIVES To compare the sensitivity of fast spin echo (FSE) and of fast fluid attenuated inversion recovery (fast FLAIR) in detecting spinal cord lesions in multiple sclerosis. METHODS With a 1.5 Tesla machine and a multicoil receiver array, FSE images (with two different pixel sizes) and fast FLAIR images of the spinal cord were obtained from 13 patients with multiple sclerosis. RESULTS Twenty three lesions (10 cervical, 12 thoracic, and one lumbar) were found in seven patients (54%) using FSE with the larger pixel size. Seventeen lesions (seven cervical and 10 thoracic) were detected in the same seven patients using FSE with smaller pixel size. Nine lesions (five cervical and four thoracic) were found using fast FLAIR in six patients (46%). All the lesions found using fast FLAIR were detected using the other two techniques and all the lesions detected by FSE with smaller pixel size were detected using FSE and greater pixel size. CONCLUSION Fast FLAIR sequences detect substantially fewer cord lesions in patients with multiple sclerosis.
منابع مشابه
The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.
PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...
متن کاملProton Density MRI Increases Detection of Cervical Spinal Cord Multiple Sclerosis Lesions Compared with T2-Weighted Fast Spin-Echo.
BACKGROUND AND PURPOSE There is a paucity of literature that supports the Consortium of Multiple Sclerosis Centers guideline that proton density MR imaging is a core spinal cord sequence. We hypothesized that proton density fast spin-echo imaging is superior to T2 fast spin-echo MR imaging for the detection of cervical cord MS lesions. This study compared the detection rate and conspicuity of c...
متن کاملSpinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
متن کاملComparison of MR pulse sequences in the detection of multiple sclerosis lesions.
PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...
متن کاملQuantitative assessment of MRI lesion load in multiple sclerosis. A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery.
In this study, we compared a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence to conventional spin-echo (CSE) in the evaluation of brain MRI lesion loads of seven patients with clinically definite multiple sclerosis. Interleaved CSE (3000/20, 5 mm contiguous axial slices) and fast-FLAIR (9000/150/2200, 5 mm contiguous axial slices) sequences were performed on a 1.0 T machine. Lesi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 61 6 شماره
صفحات -
تاریخ انتشار 1996