Is the so-called 'French paradox' a reality?: long-term survival and migration of the Charnley-Kerboull stem cemented line-to-line.

نویسندگان

  • F El Masri
  • L Kerboull
  • M Kerboull
  • J P Courpied
  • M Hamadouche
چکیده

We have evaluated the in vivo migration patterns of 164 primary consecutive Charnley-Kerboull total hip replacements which were undertaken in 155 patients. The femoral preparation included removal of diaphyseal cancellous bone to obtain primary rotational stability of the stem before line-to-line cementing. We used the Ein Bild Roentgen Analyse femoral component method to assess the subsidence of the femoral component. At a mean of 17.3 years (15.1 to 18.3) 73 patients were still alive and had not been revised, eight had been revised, 66 had died and eight had been lost to follow-up. The mean subsidence of the entire series was 0.63 mm (0.0 to 1.94). When using a 1.5 mm threshold, only four stems were considered to have subsided. Our study showed that, in most cases, a highly polished double-tapered stem cemented line-to-line does not subside at least up to 18 years after implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-Term Migration Using EBRA-FCA of Stems Cemented Line-to-Line According to the “French Paradox” Principles

Introduction: A large body of the orthopaedic literature indicates that the cement mantle surrounding the femoral component of a cemented total hip arthroplasty should be at least 2 mm thick. Another concept, introduced in the early seventies and is still in use in France, consists of implanting a canal filling femoral component line-to-line associated with a thin cement mantle. This principle ...

متن کامل

Finite element analysis of the effect of cementing concepts on implant stability and cement fatigue failure

BACKGROUND AND PURPOSE Two contradictory cementing techniques (using an undersized stem versus a canal-filling stem) can both lead to excellent survival rates, a phenomenon known as the "French paradox". Furthermore, previous studies have indicated that the type of bone supporting the cement mantle may affect implant survival. To further evaluate the mechanical consequences of variations in cem...

متن کامل

The long-term results of press-fit cemented stems in total knee prostheses.

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibioti...

متن کامل

I-18: Avian Chimeras and Germ Cell Migration

Background: In avian species, the germ line stem cell population arises outside of the embryonic gonad and proceeds on a circuitous migration to the germinal epithelium. Specifically, in the avian embryo, the process of germ line stem cell migration proceeds through a series of active and passive migratory phases. The germline stem cells or primordial germ cells (PGCs) located in the epiblast o...

متن کامل

Impaction grafting in association with the Charnley-Kerboull cemented femoral component: operative technique and two- to 16-year follow-up results.

We describe 129 consecutive revision total hip replacements using a Charnley-Kerboull femoral component of standard length with impaction allografting. The mean follow-up was 8.2 years (2 to 16). Additionally, extramedullary reinforcement was performed using struts of cortical allograft in 49 hips and cerclage wires in 30. There was one intra-operative fracture of the femur but none later. Two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2010