This paper presented a proposed design for transcutaneous inductive powering links. The design used to transfer power and data to the implanted devices such as implanted Microsystems to stimulate and monitoring the nerves and muscles. The system operated with low band frequency 13.56 MHZ according to industrialscientific – medical (ISM) band to avoid the tissue heating. For external part, the modulation index is 13 % and the modulation rate 7.3% with data rate 1 Mbit/s assuming Tbit=1us. The system has been designed using 0.35-μm fabricated CMOS technology. The mathematical model is given and the design is simulated using OrCAD P Spice 16.2 software tool and for real-time simulation the electronic workbench MULISIM 11 has been used. The novel circular plane (pancake) coils was simulated using ANSOFTHFss software. Keywords—Implanted devices, ASK techniques, Class-E power amplifier, Inductive powering and low-frequency ISM band.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcutaneous Inductive Powering Links Based on ASK Modulation Techniques

This paper presented a modified efficient inductive powering link based on ASK modulator and proposed efficient classE power amplifier. The design presents the external part which is located outside the body to transfer power and data to the implanted devices such as implanted Microsystems to stimulate and monitoring the nerves and muscles. The system operated with low band frequency 10MHZ acco...

متن کامل

Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors

Inductive powering for implanted medical devices, such as implantable biosensors, is a safe and effective technique that allows power to be delivered to implants wirelessly, avoiding the use of transcutaneous wires or implanted batteries. Wireless powering is very sensitive to a number of link parameters, including coil distance, alignment, shape, and load conditions. The optimum drive frequenc...

متن کامل

The CMOS design of a high-efficiency transcutaneous power and data system

This paper presents a proposed design for transcutaneous inductive powering links with “suspended-carrier”. The design used to transfer power and data to the implanted devices.This work describes the implementation of a 0.35μm CMOS integrated circuit using 3.3v supply dedicated to cochlear prosthesis. In the wireless biomedical implants the carrier frequency, which represent the resonant freque...

متن کامل

Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review

Wireless energy transfer is a broad research area that has recently become applicable to implantable medical devices. Wireless powering of and communication with implanted devices is possible through wireless transcutaneous energy transfer. However, designing wireless transcutaneous systems is complicated due to the variability of the environment. The focus of this review is on strategies to se...

متن کامل

Design of Inductive Coupling for Powering and Communication of Implantable Medical Devices

Technological advances over the years have made it possible to reduce the size and power consumption of electronics. This has led to significant advances for biomedical sensors. It is now possible to reduce the size enough to create implantable sensors. This type of sensors can for instance be used to measure the glucose level of diabetes patients. An implantable sensor can significantly simpli...