Quasiextremals for a Radon-like Transform
نویسنده
چکیده
where for each x in some ambient manifold, each set Mx is a smooth submanifold of a second ambient manifold,Mx varies smoothly with x, and σx is a smooth multiple of the induced surface measure on Mx. A transversality hypothesis is also imposed, guaranteeing that the transpose of T is a generalized Radon transform in the same sense. As is well known, the particular operator T defined by (1.1) maps L(d+1)/d(Rd) boundedly to Ld+1(Rd), but does not map Lp boundedly to Lq for any other exponents p, q. The localized operator
منابع مشابه
Detection of Blood Vessels in Color Fundus Images using a Local Radon Transform
Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable a...
متن کاملContent Based Image Retrieval Using Improved Radon Transform under Various Queries
Image Retrieval is very one of the biggest task in the recent years. It is widely used in many real time databases to retrieve related images in various fields like medical, military, online shopping etc. This paper offers with using radon transform followed by PCA and LDA techniques for image retrieval is called as Combined Radon Space Features Set (CRSFS). Caltech 101 database image sets used...
متن کاملOptical realization of the radon transform.
This paper presents a novel optical system for the realization of the Radon transform in a single frame. The optical system is simple, fast and accurate and consists of a 4F system, where in the 2F plane a vortex like optical element is placed. This optical element performs the rotation of the object, which replaces the need for mechanically rotating it, as is done in other common optical reali...
متن کاملMotion Artifact Compensation in CT
A new method for compensating motion artifacts in computerized tomography is presented. The algorithm operates on the raw data, that is, on the measured Radon transform. An edge detection is performed on the Radon transform image. Two curves are obtained from these edges, which are tted by a polynomial. The pointwise diierences between the edges of the Radon transform image and the tted curves ...
متن کاملAutomatic Detection of Microaneurysms in Color Fundus Images using a Local Radon Transform Method
Introduction: Diabetic retinopathy (DR) is one of the most serious and most frequent eye diseases in the world and the most common cause of blindness in adults between 20 and 60 years of age. Following 15 years of diabetes, about 2% of the diabetic patients are blind and 10% suffer from vision impairment due to DR complications. This paper addresses the automatic detection of microaneurysms (MA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007