Total disc replacement positioning affects facet contact forces and vertebral body strains.

نویسندگان

  • Steven A Rundell
  • Joshua D Auerbach
  • Richard A Balderston
  • Steven M Kurtz
چکیده

STUDY DESIGN A validated nonlinear three-dimensional finite element (FE) model of a single lumbar motion segment (L3-L4) was used to evaluate the effects of total disc replacement (TDR). The model was implanted with a fixed-bearing TDR (ProDisc-L) at 2 surgically relevant positions and exercised about the 3 anatomic axes. Facet forces, range of motion (RoM), and vertebral body strains were evaluated. OBJECTIVE The objective of the current study was to evaluate how TDR implantation and positioning affects facet joint forces and vertebral body strains. We hypothesized that facet contact forces (FCFs) would increase with TDR to compensate for the loss of periprosthetic load-bearing structures, and that vertebral body strains would increase in the region around the metallic footplates. SUMMARY OF BACKGROUND DATA TDR has the potential to replace fusion as the gold standard for the treatment of painful degenerative disc disease. However, complications after TDR include index level facet arthrosis and implant subsidence. Alterations in facet and vertebral body loading after TDR and their dependence on implant positioning are not fully understood. METHODS An FEM of L3-L4 was created and validated using RoM, disc pressure, and bony strains from previously published data. A TDR was incorporated into the L3-L4 spine model. All models were subjected to a compressive follower load of 500 N and moments of 7.5 Nm about the 3 anatomic axes. RESULTS Overall RoM and FCFs tended to increase with TDR. FCFs increased by an order of magnitude during flexion. Posterior placement of the device resulted in an unloading of the facets during extension. Areas of strain maxima were observed in the anterior portion of the vertebral body during flexion after TDR. The area of initial bone resorption signal under the metal footplate was greater when the device was anteriorly placed. CONCLUSION The current study predicted a decrease in segmental rotational stiffness resulting from TDR. This resulted from the removal of load bearing soft tissue structures, and caused increased loading in the facets. Additionally, vertebral body strains were generally higher after TDR, and tended to increase with decreased rotational stiffness. Posterior placement of the device provided a more physiologic load transfer to the vertebral body.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System) - a finite element analysis

BACKGROUND Pedicle-screw-based posterior dynamic stabilization devices are designed to alleviate the rate of accelerated degeneration of the vertebral level adjacent to the level of spinal fusion. A new pedicle-screw-based posterior dynamic stabilization device- the Awesome Dynamic Rod System was designed with curve cuts on the rods to provide flexibility. The current study was conducted to eva...

متن کامل

Biomechanical evaluation of a spherical lumbar interbody device at varying levels of subsidence

BACKGROUND Ulf Fernström implanted stainless steel ball bearings following discectomy, or for painful disc disease, and termed this procedure disc arthroplasty. Today, spherical interbody spacers are clinically available, but there is a paucity of associated biomechanical testing. The primary objective of the current study was to evaluate the biomechanics of a spherical interbody implant. It wa...

متن کامل

Clarification of the mechanical behaviour of spinal motion segments through a three-dimensional poroelastic mixed finite element model.

The purpose of this study is to clarify the mechanical behaviour of spinal motion segments through a proper numerical model. The model constructed can give correct information and provide medical fields with valuable guidance in solving clinical problems occurring in the spine. A three-dimensional poroelastic finite element model of spinal motion segments is constructed and a mixed formulation ...

متن کامل

Biomechanical comparison between lumbar disc arthroplasty and fusion.

The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements. However, inconsistent biomechanical results for the neighboring elements have been reported in a number of studies. The present study used finite element (FE) analysis to explore the biomechanical differences at the surgical and both adjacent levels follow...

متن کامل

The facet joint loading profile of a cervical intervertebral disc replacement incorporating a novel saddle-shaped articulation.

STUDY DESIGN Biomechanical study. OBJECTIVE To evaluate the cervical facet loading profile of an intervertebral cervical disc prosthesis incorporating a unique saddle-shaped articulation and to determine the effect of implantation of the prosthesis on both the loading curve and area distribution of facet loading, when compared with that of an intact specimen. SUMMARY OF BACKGROUND DATA This...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 33 23  شماره 

صفحات  -

تاریخ انتشار 2008