Image Quality Phantom in Close Compliance with the ICRU-44 Breast Tissue Substitute Standard and Realistic Background Noise Pattern for Digital Breast Tomosynthesis
نویسندگان
چکیده
Digital breast tomosynthesis (DBT) is an emerging technique that allows for slices parallel with the detector to be constructed through the breast, as opposed to two dimensional mammography. Present phantoms for use on mammography systems are two dimensional in nature and focus mainly on differences in contrast. Since tomosynthesis is a three-dimensional-technique, a suitable phantom for use on a DBT-system should contain different overlying structures, as is the case within a real breast. We present a method to construct such a three dimensional phantom from a liquid polyurethane-basis that contains overlapping masses, microcalcifications and a representative anatomical background. This way a representative quantitative phantom could be constructed for image quality control on a DBT-system.
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملA study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کاملMonte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost
Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...
متن کاملConsideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation
Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...
متن کاملRestoration of Low-Dose Digital Breast Tomosynthesis
In breast cancer screening, the radiation dose must be kept to the minimum necessary to achieve the desired diagnostic objective, thus minimizing risks associated with cancer induction. However, decreasing the radiation dose also degrades the image quality. In this work we restore digital breast tomosynthesis (DBT) projections acquired at low radiation doses with the goal of achieving a quality...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010