Automated FiO2-SpO2 control system in Neonates requiring respiratory support: a comparison of a standard to a narrow SpO2 control range
نویسندگان
چکیده
BACKGROUND Managing the oxygen saturation of preterm infants to a target range has been the standard of care for a decade. Changes in target ranges have been shown to significantly impact mortality and morbidity. Selecting and implementing the optimal target range are complicated not only by issues of training, but also the realities of staffing levels and demands. The potential for automatic control is becoming a reality. Results from the evaluation of different systems have been promising and our own experience encouraging. METHODS This study was conducted in two tertiary level newborn nurseries, routinely using an automated FiO2-SpO2 control system (Avea-CLiO2, Yorba Linda CA, USA). The aim of this study was to compare the performance of the system as used routinely (set control range of 87-93% SpO2), to a narrower higher range (90-93%). We employed a 12-hour cross-over design with the order of control ranges randomly assigned for each of up to three days. The primary prospectively identified end points were time in the 87-93% SpO2 target range, time at SpO2 extremes and the distribution of the SpO2 exposure. RESULTS Twenty-one infants completed the study. The infants were born with a median EGA of 27 weeks and studied at a median age of 17 days and weight of 1.08 kg. Their median FiO2 was 0.32; 8 were intubated, and the rest noninvasively supported (7 positive pressure ventilation and 6 CPAP). The control in both arms was excellent, and required less than 2 manual FiO2 adjustments per day. There were no differences in the three primary endpoints. The narrower/higher set control range resulted in tighter control (IQR 3.0 vs. 4.3 p < 0.001), and less time with the SpO2 between 80-86 (6.2% vs. 8.4%, p = 0.006). CONCLUSIONS We found that a shift in the median of the set control range of an automated FiO2-SpO2 control system had a proportional effect on the median and distribution of SpO2 exposure. We found that a dramatic narrowing of the set control range had a disproportionally smaller impact. Our study points to the potential to optimize SpO2 targeting with an automated control system.
منابع مشابه
Automated versus Manual Oxygen Control with Different Saturation Targets and Modes of Respiratory Support in Preterm Infants.
OBJECTIVE To determine the efficacy and safety of automated adjustment of the fraction of inspired oxygen (FiO2) in maintaining arterial oxygen saturation (SpO2) within a higher (91%-95%) and a lower (89%-93%) target range in preterm infants. STUDY DESIGN Eighty preterm infants (gestational age [median]: 26 weeks, age [median] 18 days) on noninvasive (n = 50) and invasive (n = 30) respiratory...
متن کاملFeasibility and reliability of an automated controller of inspired oxygen concentration during mechanical ventilation
INTRODUCTION Hypoxemia and high fractions of inspired oxygen (FiO2) are concerns in critically ill patients. An automated FiO2 controller based on continuous oxygen saturation (SpO2) measurement was tested. Two different SpO2-FiO2 feedback open loops, designed to react differently based on the level of hypoxemia, were compared. The results of the FiO2 controller were also compared with a histor...
متن کاملValidity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome
Introduction: One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio. Methods and Materials: In a cross sectional study we enrolled 105 sample o...
متن کاملAutonomous control of inspired oxygen concentration during mechanical ventilation of the critically injured trauma patient.
BACKGROUND Transport of mechanically ventilated patients in a combat zone presents challenges including conservation of resources. In the battlefield setting, the provision of adequate oxygen supplies remains a significant issue. Autonomous control of oxygen concentration may allow a reduction in mission load. METHODS Trauma patients requiring ventilation and inspired oxygen concentration (FI...
متن کاملS(pO2) Histograms in Preterm Infants: A Helpful Tool for Neonatologists?
In recent years, oxygen targeting has become a relevant topic in neonatal intensive care medicine.1 Despite large SpO2 targeting trials including numerous subjects and the available results of a meta-analysis of these data,2,3 there is still an ongoing debate on the optimum SpO2 target range in preterm infants. Both conditions, hyperoxia as well as hypoxia, frequently occur in extremely low bir...