Analysis of Draize Eye Irritation Testing and its Prediction by Mining Publicly Available 2008–2014 REACH Data

نویسندگان

  • Thomas Luechtefeld
  • Alexandra Maertens
  • Daniel P. Russo
  • Costanza Rovida
  • Hao Zhu
  • Thomas Hartung
چکیده

Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retesting of substances. This allowed assessment of the test's reproducibility test based on all substances tested more than once. There was a 10% chance of a non-irritant evaluation given after a prior severe-irritant result as given by UN GHS classification criteria. The most reproducible outcomes were the results negative (94% reproducible) and severe eye irritant (73% reproducible). To evaluate whether other GHS categorizations predict eye irritation we built a dataset of 5,629 substances (1,931 'irritant' and 3,698 'non-irritant'). The two best decision trees with up to three other GHS classifications resulted in balanced accuracies of 68% and 73%, i.e., in the rank order of the Draize rabbit eye test itself, but both use inhalation toxicity data ("May cause respiratory irritation"), which is not typically available. Next, a dataset of 929 substances with at least one Draize study was mapped to PubChem to compute chemical similarity using 2D conformational fingerprints and Tanimoto similarity. Using a minimum similarity of 0.7 and simple classification by the closest chemical neighbor resulted in balanced accuracy from 73% over 737 substances to 100% at a threshold of 0.975 over 41 substances. This represents a strong support of read-across and (Q)SAR approaches in this area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Draize Eye Irritation Testing and its Prediction by Mining Publicly Available 2008 - 2014 REACH Data 1

Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retestin...

متن کامل

First alternative method validated by a retrospective weight-of-evidence approach to replace the Draize eye test for the identification of non-irritant substances for a defined applicability domain.

A replacement alternative to the rabbit eye irritation test has been sought for many years. First published in 1944 by FDA toxicologist J. H. Draize, the test, now known as the Draize Eye Test, has been used extensively to assess eye safety. It has also been a focal point for concern regarding its animal use. In 1992, Molecular Devices developed the Cytosensor Microphysiometer (CM) technology, ...

متن کامل

Repeated exposure to benzalkonium chloride in the Ex Vivo Eye Irritation Test (EVEIT): observation of isolated corneal damage and healing.

The prediction of side-effects is a key issue in the REACH initiative on chemicals, in the production of cosmetics and in the preclinical testing of drugs. A new ex vivo test for repeated substance application is presented, that is able to identify corrosive and irritant effects on the eye by using crucial endpoints, such as cellular and morphological damage, and healing characteristics. The te...

متن کامل

Corneal Models for the Toxicity Testing of Drugs and Drug Releasing Materials

T he Draize rabbit eye irritation test developed in the 1940’s is even today the only eye toxicity test officially accepted in the OECD countries for regulatory purposes in the classification of slightly and moderately irritating chemicals. It is based on the subjective scoring of three tissues of the eye: the cornea, the conjunctiva and the iris. The Draize test has been widely criticized for ...

متن کامل

Combined in vitro tests as an alternative to in vivo eye irritation tests.

Accurate methods that test the eye irritation potential of chemicals, which do not involve the use of animals, are needed to meet new regulatory standards. We evaluated the applicability and predictive capacity of five in vitro tests for eye irritation: the Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) assay; the Chorioallantoic Membrane-Trypan Blue Staining (CAM-TBS) assay; the Fluorescein...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2016