Susceptibility of Radon Measurement Devices to Electric Fields
نویسندگان
چکیده
This paper examines the possible occurrence of errors due to electromagnetic interferences during radon air concentration measurements. Using SIMULINK, two measurement methods were simulated and compared in terms of their susceptibility to perturbations. After analyzing the detection chamber and the analogue input stage, a method for eliminating the parasitic pulses passing through two measurement channels is described. The subsequent measurements were performed in areas exposed to high electromagnetic field levels and then compared with results obtained in areas with lesser exposure to electromagnetic fields. Two sets of final measurement results were presented by using alternatively an electronic measuring device as well as track detectors.
منابع مشابه
طراحی و ساخت دستگاه اندازه گیری شدت میدان های الکتریکی و مغناطیسی به منظور ارزیابی سلامت شاغلین و مردمِ در معرض این میدان ها
In the extremely low frequency range (3 to 300 Hz), the intensities of electric and magnetic fields increase with increasing voltage and current. If the intensities of electric and magnetic fields are high compared with standard exposure limits, they can have harmful effects on human health. In the vicinity of power lines and high voltage power stations, the intensities of these fields are usua...
متن کاملMeasurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector
The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...
متن کاملCalculating CR-39 Response to Radon in Water Using Monte Carlo Simulation
Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...
متن کاملIndoor radon survey in Shiraz-Iran using developed passive measurement method
Background: While in the open air the amount of radon gas is very small and does not pose a health risk, in confined spaces, radon can accumulate to relatively high levels and become a health hazard. Exposure to high levels of radon has been associated with an increased risk of lung cancer, depending on the time length of exposure. Radon level in dwelling of Shiraz with 1,200,000 popul...
متن کاملMonte-Carlo Calculation of Radon Absorbed Dose in Optical Fiber as a Novel Method in Dosimetry and Radon Measurement
Introduction Radon is a colorless and tasteless gas which exists in most soils. It is a substance that poses a potential risk for lung cancer in case a person is exposed to high levels over long periods of time. The Environmental Protection Agency (EPA) estimates that 90% of lung cancers per year are caused by radon. The aim of this paper is to estimate the absorbed doses of 222Rn by MCNPX simu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013