Control Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements

نویسندگان

  • Y. Kusuma Latha
  • Ch. Saibabu
  • Y. P. Obulesh
چکیده

The active power filter has been proved to be an effective method to mitigate harmonic currents generated by nonlinear loads as well as to compensate reactive power. The methods of harmonic current detection play a crucial part in the performance of active power filter (APF). This paper presents a new control strategy in which two shunt active power filter configurations are developed in order to define new simple control algorithm which requires minimum number of current measurements. The effectiveness of the proposed control strategies are demonstrated through results. The proposed systems are implemented with MATLAB/SIMULINK. The simulation results are presented for two control strategies and comparison is made among them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

ارائۀ روش کنترلی جدید برای فیلترهای اکتیو موازی در سیستم‌های سه‌فاز چهارسیمه به‌منظور جبران‌سازی هارمونیک‌ها، نامتعادلی و توان راکتیو

In this paper, a novel control strategy for a Shunt Active Power Filter (shunt-APF) is proposed. In the proposed control strategy which is based on a new application of the instantaneous reactive power theory, the current injected by the shunt-APF is capable of compensation for the reactive component, the harmonic components and also unbalance of the load current. In this strategy, the shunt-AP...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks

The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011