Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared-rapid gradient-echo sequence.
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to evaluate a magnetization-prepared-rapid gradient-echo (MP-RAGE) sequence as a three-dimensional (3D) T1-weighted MR imaging technique to reveal lymph node metastases from carcinoma of the bladder and the prostate. SUBJECTS AND METHODS Using a 3D T1-weighted MP-RAGE sequence, MR images of 134 consecutive patients with prostatic carcinoma (n = 63) or urinary bladder carcinoma (n = 71) who were scheduled for radical prostatectomy or radical cystectomy were correlated with histopathologic findings after fine-needle aspiration biopsy (FNAB) (n = 6), open or laparoscopic pelvic lymph node dissection (n = 127), or autopsy (n = 1). MR imaging was used 10 times to guide FNAB in nine patients. RESULTS The sensitivity, specificity, accuracy, and positive predictive valve of the technique were 75%, 98%, 90%, and 94%, respectively. Thin-slice (1.2-mm) multiplanar reconstructed images correctly revealed diseased nodes in 33 patients. However, MR imaging failed to reveal microscopic metastatic deposits in normally sized nodes in 11 patients. Two other patients had enlarged nodes without metastasis. Furthermore, FNAB guided by MR imaging revealed metastases in six of nine patients. CONCLUSION MR imaging with a 3D MP-RAGE sequence was accurate in revealing nodal metastases from carcinoma of the prostate and bladder. This imaging technique can be used to select patients for biopsy or laparoscopic pelvic lymph node dissection.
منابع مشابه
Staging urinary bladder cancer: value of T1-weighted three-dimensional magnetization prepared-rapid gradient-echo and two-dimensional spin-echo sequences.
OBJECTIVE The purpose of this study was to evaluate a magnetization prepared-rapid gradient-echo (MP-RAGE) sequence as a three-dimensional T1-weighted MR imaging technique for staging urinary bladder cancer and to compare this technique with a commonly used two-dimensional T1-weighted spin-echo sequence technique. SUBJECTS AND METHODS For 28 consecutive patients with urinary bladder cancer, M...
متن کاملIncreased spatial resolution using a three-dimensional T1-weighted gradient-echo MR sequence results in greater hypointense lesion volumes in multiple sclerosis.
PURPOSE Our goal was to evaluate whether improved spatial resolution of MR images results in the detection of higher volumes of hypointense lesions in patients with multiple sclerosis (MS). METHODS A magnetization-prepared rapid acquisition gradient-echo (MP-RAGE) sequence with subsequent reconstruction of axial sections with 5-, 3-, and 1-mm thickness and a dual-echo sequence were obtained i...
متن کاملThree-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination.
BACKGROUND AND PURPOSE T1-weighted, 3D gradient-echo MR sequences can be optimized for rapid acquisition and improved resolution through asymmetric k-space sampling and interpolation. We compared a volumetric interpolated brain examination (VIBE) sequence with a magnetization-prepared rapid acquisition gradient echo (MP RAGE) sequence and a 2D T1-weighted spin-echo (SE) sequence. METHODS Thir...
متن کاملT1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.
PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...
متن کاملThe effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJR. American journal of roentgenology
دوره 167 6 شماره
صفحات -
تاریخ انتشار 1996