Generation of a flat-top laser beam for gravitational wave detectors by means of a nonspherical Fabry-Perot resonator.

نویسندگان

  • Marco G Tarallo
  • John Miller
  • J Agresti
  • E D'Ambrosio
  • R DeSalvo
  • D Forest
  • B Lagrange
  • J M Mackowsky
  • C Michel
  • J L Montorio
  • N Morgado
  • L Pinard
  • A Remilleux
  • B Simoni
  • P Willems
چکیده

We have tested a new kind of Fabry-Perot long-baseline optical resonator proposed to reduce the thermal noise sensitivity of gravitational wave interferometric detectors--the "mesa beam" cavity--whose flat top beam shape is achieved by means of an aspherical end mirror. We present the fundamental mode intensity pattern for this cavity and its distortion due to surface imperfections and tilt misalignments, and contrast the higher order mode patterns to the Gauss-Laguerre modes of a spherical mirror cavity. We discuss the effects of mirror tilts on cavity alignment and locking and present measurements of the mesa beam tilt sensitivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An experimental demonstration of resonant sideband extraction for laser-interferometric gravitational wave detectors

Resonant sideband extraction is a new optical configuration for laser-interferometric gravitational wave detectors with Fabry-Perot cavities in the arms. It reduces the thermal load on the beam splitter and the coupling mirrors of the cavities and also allows one to adapt the frequency response of the detector to a variety of requirements. We report the first experimental demonstration using a ...

متن کامل

Diffractive Optics for Gravitational Wave Detectors

All-reflective interferometry based on nano-structured diffraction gratings offers new possibilities for gravitational wave detection. We investigate an all-reflective Fabry-Perot interferometer concept in 2nd order Littrow mount. The input-output relations for such a resonator are derived treating the grating coupler by means of a scattering matrix formalism. A low loss dielectric reflection g...

متن کامل

Mirror-orientation noise in a Fabry-Perot interferometer gravitational wave detector.

The influence of angular mirror-orientation errors on the length of a Fabry-Perot resonator is analyzed geometrically. Under conditions in which dominant errors are static or vary slowly over time, the analysis permits a simple prediction of the spectrum of short-term cavity length fluctuations resulting from mirror-orientation noise. The resulting model is applicable to the design of mirror co...

متن کامل

Shot noise in gravitational-wave detectors with Fabry-Perot arms.

Shot-noise-limited sensitivity is calculated for gravitational-wave interferometers with Fabry-Perot arms, similar to those being installed at the Laser Interferometer Gravitational-Wave Observatory (LIGO) and the Italian-French Laser Interferometer Collaboration (VIRGO) facility. This calculation includes the effect of nonstationary shot noise that is due to phase modulation of the light. The ...

متن کامل

Design and construction of a prototype of a flat top beam interferometer and initial tests

A non-Gaussian, flat-top laser beam profile, also called Mesa Beam Profile, supported by non spherical mirrors known as Mexican Hat (MH) mirrors, has been proposed as a way to depress the mirror thermal noise and thus improve the sensitivity of future interferometric Gravitational Wave detectors, including Advanced LIGO [1]. Non-Gaussian beam configurations have never been tested before [2] hen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 46 26  شماره 

صفحات  -

تاریخ انتشار 2007