Analytical study of comprehensive and targeted multidimensional gas chromatography incorporating modulated cryogenic trapping.

نویسندگان

  • T T Truong
  • P J Marriott
  • N A Porter
چکیده

This paper reports the results of an analytical study comparing capillary gas chromatography (GC) operated in the normal mode with 2 new GC techniques, comprehensive GC (GC x GC) and targeted (or selective) multidimensional GC, which use a longitudinally modulated cryogenic system (LMCS), recently developed in our laboratory. A high-temperature application of derivatized sterols, of interest in fecal pollution monitoring, was chosen for this work. A directly connected coupled-column ensemble was used, comprising a nonpolar column and a moderately polar column. With LMCS, effluent from the first column is zone-compressed in a cryogenic trap and then pulsed to a short second column, producing narrower peaks with sharp, tall peak responses at the detector. The modulator is operated at a constant frequency, e.g., 0.25 s(-1), to produce the GC x GC result, or is moved in a predefined manner so that whole peaks are selectively trapped and subsequently pulsed through to the second column in the targeted mode. Standard solutions containing a mixture of 7 sterols and 5-alpha-cholestane internal standard were used. Detection sensitivity is increased by a factor of >25 with the use of LMCS. The estimated limit of detection was about 0.1 microg/mL when normal GC with flame ionization detection (GC/FID) and a 1.0 microL splitless injection volume were used, compared with 0.02 and 0.004 microg/mL for the LMCS operated in GC x GC and selective modes, respectively. Calibration curves for GC/FID were linear over the 0.1-2.0 microg/mL range tested. Reproducibilities for the GC x GC and normal GC modes were comparable; generally, relative standard deviations (RSD) were on the order of 3-4%, based on raw peak responses. Improved reproducibility was found for selective LMCS operation, at an RSD of around 2%; with internal standardization, better results were achieved. The coupled-column arrangement allowed complete separation of sterol peaks from overlapping impurity peaks in a number of instances with LMCS modes, and its use should improve data quality over that of normal GC operation, in which the overlapping peaks interfere with measurement of peak response in the normal mode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive two-dimensional gas chromatography and food sensory properties: potential and challenges.

Modern omics disciplines dealing with food flavor focus the analytical efforts on the elucidation of sensory-active compounds, including all possible stimuli of multimodal perception (aroma, taste, texture, etc.) by means of a comprehensive, integrated treatment of sample constituents, such as physicochemical properties, concentration in the matrix, and sensory properties (odor/taste quality, p...

متن کامل

Simultaneous deconvolution and re-construction of primary and secondary overlapping peak clusters in comprehensive two-dimensional gas chromatography.

In this study, simultaneous deconvolution and reconstruction of peak profiles in the first ((1)D) and second dimension ((2)D) of comprehensive two-dimensional (2D) gas chromatography (GC×GC) is achieved on the basis of the property of this new type of instrumental data. First, selective information, where only one component contributes to the peak elution window of a given modulation event, is ...

متن کامل

Detection of an Extended Human Volatome with Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry

BACKGROUND Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GCxGC-TOF MS) has been proposed as a powerful new tool for multidimensional analysis of complex chemical mixtures. We investigated GCxGC-TOF MS as a new method for identifying volatile organic compounds (VOCs) in normal human breath. METHODS Samples of alveolar breath VOCs and ambient ro...

متن کامل

Integrating reaction and analysis: investigation of higher-order reactions by cryogenic trapping

A new approach for the investigation of a higher-order reaction by on-column reaction gas chromatography is presented. The reaction and the analytical separation are combined in a single experiment to investigate the Diels-Alder reaction of benzenediazonium-2-carboxylate as a benzyne precursor with various anthracene derivatives, i.e. anthracene, 9-bromoanthracene, 9-anthracenecarboxaldehyde an...

متن کامل

Combined untargeted and targeted fingerprinting with comprehensive two-dimensional chromatography for volatiles and ripening indicators in olive oil.

Comprehensive two-dimensional gas chromatography (GC × GC) is the most effective multidimensional separation technique for in-depth investigations of complex samples of volatiles (VOC) in food. However, each analytical run produces dense, multi-dimensional data, so elaboration and interpretation of chemical information is challenging. This study exploits recent advances of GC × GC-MS chromatogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 2  شماره 

صفحات  -

تاریخ انتشار 2001