Relation between mixed venous oxygen saturation and cardiac index. Nonlinearity and normalization for oxygen uptake and hemoglobin.
نویسندگان
چکیده
The ability of mixed venous oxygen saturation (SvO2) monitoring to reflect changes in cardiac index (CI) with therapy in critically ill patients is unclear. To this end, SvO2 and CI were measured before and during an infusion of enoximone and/or dobutamine in 30 patients with advanced heart failure. A nonlinear relationship was observed between SvO2 and CI with the nonlinear correlation coefficient being 0.52. On normalizing for individual differences in hemoglobin and oxygen consumption, this correlation coefficient became 0.90. Further analysis of individual data was performed using linear regression, and the slopes and correlation coefficients were found to span a wide range slope: -10.0 to 30.9 min-m2/L, r: -0.27 to 0.99). However, the mean slope and correlation coefficient for patients with baseline CI and SvO2 less than 21/min/m2 and less than 55 percent were 18.3 min-m2/L and 0.87, respectively, while those for the remainder of patients were only 3.1 min-m2/L and 0.42, respectively. Thus, the nonlinear correlation coefficient of the SvO2-CI relationship in a group of patients is dependent on the homogeneity of their oxygen consumption and hemoglobin concentration. Furthermore, the ability of SvO2 to serve as a therapeutic indicator in any given patient is dependent on baseline SvO2 and CI.
منابع مشابه
Correlation of mixed venous and central venous oxygen saturation and its relation to cardiac index
Background and Aim: The clinical applicability of substitution of central venous oxygen saturation for mixed venous oxygen saturations in monitoring global tissue hypoxia is still a matter of controversy. Hence aim of the study is comparison of paired samples of mixed venous and central venous oxygen saturation and comparison in relation to cardiac index in varying hemodynamic conditio s. Mater...
متن کاملInfluence of cardiac output on the correlation between mixed venous and central venous oxygen saturation.
The influence of cardiac output on the correlation between central venous oxygen saturation and mixed venous oxygen saturation was assessed in 51 patients who had both a pulmonary artery catheter and separate central venous catheter in situ. Seventy-six paired samples were taken from the catheters and oxygen saturation measured immediately in a Ciba Corning 2500 Co-oximeter. Cardiac output was ...
متن کاملValidity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملThe effect of cardiac disease on hemoglobin-oxygen binding.
The relation between degree of cardiac functional impairment and changes in hemoglobin-oxygen affinity and 2,3-diphosphoglycerate (2,3-DPG) has been studied in 39 patients with noncyanotic heart disease. A progressive decline in hemoglobin-oxygen affinity was found with worsening cardiac function as assessed by cardiac index, arteriovenous oxygen (A-V O(2)) difference, and cardiac symptoms; thi...
متن کاملمقایسه اندازهگیری اشباع اکسیژن خون شریانی با پالس اکسیمتری و نمونه خون شریانی در بیماران بخش مراقبتهای ویژه قلبی
Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation) in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2) during clinical routine in such patients, and to examine the eff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 99 6 شماره
صفحات -
تاریخ انتشار 1991