Establishing a rabbit spinal tumor model for nonvascular interventional therapy through CT-guided percutaneous puncture inoculation.

نویسندگان

  • L Chen
  • J Xiao
  • I-C Su
  • Y-W Wu
  • B Zhang
  • K-Y Ge
  • Y-C Chang
  • C Yang
  • C-F Ni
چکیده

BACKGROUND AND PURPOSE An animal spinal tumor model is needed to better simulate the clinical situation and to allow percutaneous puncture, which may provide an experimental platform for the new nonvascular interventional therapies. We established a rabbit spinal tumor model through a CT-guided percutaneous puncture inoculation technique for nonvascular interventional therapy. MATERIALS AND METHODS VX2 tumor cells were inoculated into the lumbar vertebrae of 32 rabbits through a CT-guided percutaneous puncture technique; then, the development of hind limb paraparesis was observed in the rabbits twice a day. MR imaging and CT were performed on days 14, 21, and 28 postinoculation and at the development of hind limb paraparesis. On days 21 and 28 postinoculation, 2 rabbits, whose imaging suggested successful modeling without hind limb paraparesis, were chosen on each day. The lumbar vertebrae were sampled from 1 rabbit for histopathologic examination, and the other rabbit underwent PET-CT examination before percutaneous vertebroplasty. Finally the lesion vertebrae were sampled for histopathologic examination. RESULTS The success rate of modeling was 90.6% (29/32) in our study. On day 21 postinoculation, successful modeling was achieved in 21 rabbits, with 19 having no hind limb paraparesis. On day 28 postinoculation, another 7 achieved successful modeling, and only 1 developed hind limb paraparesis. Percutaneous vertebroplasty treatment was successful for the 2 rabbit models. CONCLUSIONS Establishment of a rabbit spinal tumor model through a CT-guided percutaneous puncture technique and inoculation of VX2 tumor is easy and has a high success rate. The established model can be used to study nonvascular interventional therapies for spinal tumor, including percutaneous vertebroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Minimally Invasive Technique to Create a Rabbit VX2 Lung Tumor Model for Nano-Sized Image Contrast and Interventional Studies

BACKGROUND The rabbit VX2 lung cancer model is a large animal model useful for preclinical lung cancer imaging and interventional studies. However, previously reported models had issues in terms of invasiveness of tumor inoculation, control of tumor aggressiveness and incidence of complications. PURPOSE We aimed to develop a minimally invasive rabbit VX2 lung cancer model suitable for imaging...

متن کامل

Role of percutaneous nonvascular Interventional Radiology treatments in musculoskeletal lesions

Many new, minimally invasive interventional radiology procedures are now viable alternatives to traditional invasive therapy. These interventional radiological procedures can be performed in the outpatient setting and the overall cost to the patient may be less in the long run. Radiofrequency and Laser ablation techniques are now widely used and rapidly expanding technologies in the interventio...

متن کامل

Navigated CT-guided interventions.

Diagnostic and therapeutic CT- guided percutaneous interventions are clinical routine in interventional radiology. Image-guided navigation systems visualize the internal anatomy during interventions in real time not necessitating continuous image acquisition. Although multiple 3D image-guidance devices have been developed and used by several surgical disciplines in the last few years, they have...

متن کامل

Percutaneous nephrolithotripsy: C-arm CT with 3D virtual navigation in non-dilated renal collecting systems.

PURPOSE We aimed to evaluate the clinical superiority of using C-arm computed tomography (CT) to establish percutaneous nephrolithotripsy (PCNL) access for patients with non-dilated renal collecting systems. METHODS From May 2014 to May 2015, 33 patients underwent C-arm CT-guided puncture to establish PCNL access after failed attempts of ultrasonography-guided nephrostomy. Technical success, ...

متن کامل

Percutaneous Ultrasound Guided Implantation of VX2 for Creation of a Rabbit Hepatic Tumor Model

Creation of a VX2 tumor model has traditionally required a laparotomy and surgical implantation of tumor fragments. Open surgical procedures are invasive and require long procedure times and recovery that can result in post-operative morbidity and mortality. The purpose of this study is to report the results of a percutaneous ultrasound guided method for creation of a VX2 model in rabbit livers...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2015