Impact of closed minimal extracorporeal circulation on microvascular tissue perfusion during surgical aortic valve replacement: intravital imaging in a prospective randomized study.

نویسندگان

  • Peter Donndorf
  • Hannah Park
  • Brigitte Vollmar
  • Angela Alms
  • Philipp Gierer
  • Gustav Steinhoff
  • Alexander Kaminski
چکیده

OBJECTIVES Closed minimal extracorporeal circulation (MECC) systems currently do not represent the standard of surgical care for open-heart surgery. Yet, considering the beneficial results reported for coronary artery bypass graft (CABG) surgery, we used an MECC system in aortic valve replacement (AVR) and analysed the effects on intraoperative microvascular perfusion in comparison with conventional open extracorporeal circulation (CECC). METHODS In the current study, we analysed alterations in microvascular perfusion at 4 predefined time points (T1-T4) during surgical AVR utilizing orthogonal polarization spectral (OPS) imaging. Twenty patients were randomized for being operated on utilizing either MECC or CECC. Changes in functional capillary density (FCD, cm/cm(2)), mircovascular blood flow velocity (mm/s) and vessel diameter (μm) were analysed by a blinded investigator. RESULTS After the start of extracorporeal circulation and aortic cross-clamping (T2), both groups showed a significant drop in FCD, but with a significantly higher FCD in the MECC group (153.1 ± 15.0 cm/cm² in the CECC group vs 160.8 ± 12.2 cm/cm² in the MECC group, P = 0.034). During the late phase of the cardiopulmonary bypass (CPB) (T3), the FCD was still significantly depressed in both treatment groups (153.5 ± 14.6 cm/cm² in the CECC group, P <0.05 vs 'T1'; 159.5 ± 12.4 cm/cm² in the MECC group, P <0.05 versus 'T1'). After termination of CPB (T4), the FCD recovered in both groups to baseline values. Microvascular blood flow velocity tended to remain at a higher level in the MECC group, whereas haemodilution during CPB was significantly reduced in the MECC group. CONCLUSIONS The use of MECC in AVR did not affect procedural safety and, resulted in beneficial preservation of microvascular blood flow velocity and significantly reduced haemodilution during CPB. In contrast to CABG surgery, the use of MECC did not improve FCD during surgical AVR. Clinical advantages possibly resulting from attenuated haemodilution and preservation of microvascular blood flow velocity require further validation in larger patient cohorts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One stage surgical treatment of aortic valve disease and aortic coarctation with aortic bypass grafting through the diaphragm and aortic valve replacement

OBJECTIVES To validate ascending aorta-lower abdominal aorta bypass grafting treatment for patients with descending aortic coarctation and an aortic valve disease. METHODS The three patients in whom a descending atypical aortic coarctation was associated with an aortic valve disease were treated with one stage surgical treatment with aortic bypass grafting through the diaphragm and aortic val...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Valve replacement or repair in mitral and aortic heart disease.

INTRODUCrION Among the advances in medical science of the last decade is the repair or replacement of the mitral, aortic or tricuspid valve. Progress in this field was made after the introduction of the extracorporeal circulation and perfusion techniques (Key et al 1958). Under direct vision, evaluation of valve dysfunction can be accurately determined and so adequate correction is achieved (Mo...

متن کامل

Technical Approach Determines Inflammatory Response after Surgical and Transcatheter Aortic Valve Replacement

OBJECTIVE To investigate the periprocedural inflammatory response in patients with isolated aortic valve stenosis undergoing surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI) with different technical approaches. MATERIAL AND METHODS Patients were prospectively allocated to one of the following treatments: SAVR using conventional extracorporeal circulat...

متن کامل

[Percutaneous aortic aortic valve replacement: myth or reality?].

Aortic valve replacement with mechanical or biological prosthesis with extracorporeal circulation is the gold-standard for the treatment of calcific aortic stenosis. Although the results are excellent with the conventional approach some elderly patients, with multiple high-risk comorbid conditions, reoperations and severe left ventricular dysfunction have high surgical risk. During the last yea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2014