Abnormal gel flotation caused by contrast media during adrenal vein sampling

نویسندگان

  • Gabriel Lima-Oliveira
  • Giuseppe Lippi
  • Gian Luca Salvagno
  • Matteo Gelati
  • Antonella Bassi
  • Alberto Contro
  • Francesca Pizzolo
  • Gian Cesare Guidi
چکیده

INTRODUCTION During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. MATERIALS AND METHODS A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to
confirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. RESULTS At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm3 of density, was used close to the right adrenal vein due to some difficulty to access it. CONCLUSION The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated
contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organ dose in kidney imaging with contrast media

Introduction:Intravenous urography (IVU) test includes high number of images and extended imaging size. These make IVU as a diagnostic method with high absorbed doses by sensitive organs such as intestine and gonads in pelvic-abdominal area. In this study absorbed doses of pelvic-abdomen sensitive organs such as Adrenal, Bladder, Colon and Gonads in IVU test. <stron...

متن کامل

Transient visuospatial disorder from angiographic contrast.

BACKGROUND The blood-brain barrier may be permeable under the clinical settings of uncontrolled hypertension, renal insufficiency, immunosuppressive drugs, and intravascular radiographic contrast. Some reversible neurological complications after angiography are caused by cortical penetration of contrast media detected on brain computed tomographic (CT) scans. OBJECTIVES To describe the first ...

متن کامل

Rapid cortisol assay during adrenal vein sampling in patients with primary aldosteronism.

BACKGROUND Adrenal vein sampling is considered the gold standard test to identify primary aldosteronism, the most frequent form of secondary hypertension. Technical difficulties with this procedure may be overcome by monitoring cortisol concentrations in the different sampling sites during catheterization. METHODS We applied a rapid automated cortisol assay performed on a benchtop immunoassay...

متن کامل

بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا

Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimizatio...

متن کامل

Plasma metanephrine for assessing the selectivity of adrenal venous sampling.

Adrenal vein sampling is used to establish the origins of excess production of adrenal hormones in primary aldosteronism. Correct catheter positioning is confirmed using adrenal vein measurements of cortisol, but this parameter is not always reliable. Plasma metanephrine represents an alternative parameter. The objective of our study was to determine the use of plasma metanephrine concentration...

متن کامل