Accuracy and precision of MR blood oximetry based on the long paramagnetic cylinder approximation of large vessels.

نویسندگان

  • Michael C Langham
  • Jeremy F Magland
  • Charles L Epstein
  • Thomas F Floyd
  • Felix W Wehrli
چکیده

An accurate noninvasive method to measure the hemoglobin oxygen saturation (%HbO(2)) of deep-lying vessels without catheterization would have many clinical applications. Quantitative MRI may be the only imaging modality that can address this difficult and important problem. MR susceptometry-based oximetry for measuring blood oxygen saturation in large vessels models the vessel as a long paramagnetic cylinder immersed in an external field. The intravascular magnetic susceptibility relative to surrounding muscle tissue is a function of oxygenated hemoglobin (HbO(2)) and can be quantified with a field-mapping pulse sequence. In this work, the method's accuracy and precision was investigated theoretically on the basis of an analytical expression for the arbitrarily oriented cylinder, as well as experimentally in phantoms and in vivo in the femoral artery and vein at 3T field strength. Errors resulting from vessel tilt, noncircularity of vessel cross-section, and induced magnetic field gradients were evaluated and methods for correction were designed and implemented. Hemoglobin saturation was measured at successive vessel segments, differing in geometry, such as eccentricity and vessel tilt, but constant blood oxygen saturation levels, as a means to evaluate measurement consistency. The average standard error and coefficient of variation of measurements in phantoms were <2% with tilt correction alone, in agreement with theory, suggesting that high accuracy and reproducibility can be achieved while ignoring noncircularity for tilt angles up to about 30 degrees . In vivo, repeated measurements of %HbO(2) in the femoral vessels yielded a coefficient of variation of less than 5%. In conclusion, the data suggest that %HbO(2) can be measured reproducibly in vivo in large vessels of the peripheral circulation on the basis of the paramagnetic cylinder approximation of the incremental field.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the cylinder approximation for susceptometric measurement of intravascular oxygen saturation.

Susceptometry-based MR oximetry has previously been shown suitable for quantifying hemoglobin oxygen saturation in large vessels for studying vascular reactivity and quantification of global cerebral metabolic rate of oxygen utilization. A key assumption underlying this method is that large vessels can be modeled as long paramagnetic cylinders. However, bifurcations, tapering, noncircular cross...

متن کامل

Creep Strain and Stress Analysis in Laminated Composite Pres-sure Vessels

This study investigates the time-dependent long-term creep strain in a composite cylinder made of glass/vinylester with a unidirectional ply. The cylinder is subjected to an internal pressure and the boundary condition is free–free and acts as thermal insulation. The classical lamination theory (CLT) is used to derive the governing equations as a second-order equation to determine the radial, c...

متن کامل

Could We Characterize Fine Structures in Human Brain Using High-resolution Magnitude and Phase image at 7 Tesla In Vivo?

[Introduction] The high-field scanner (≥ 7T) has potential advantages of high SNR, CNR, and spatial-resolution in human brain imaging. MR magnitude and phase image at 7T shown the unprecedented high T2*-weighted contrast in deoxygenated vessels [1, 2] and iron-deposit region such as basal ganglia or deep brain nucleus [3]. While the magnitude signal is determined by T2* relaxation time, proton-...

متن کامل

Precision Closed-form Solution for Out-of-plane Vibration of Rectangular Plates via Trigonometric Shear Deformation Theory

In this study, the new refine trigonometric shear deformation plate theory is used to study the out-of-plane vibration of the rectangular isotropic plates with different boundary conditions. The novelty of the research is that the analytical precision closed-form solution is developed without any use of approximation for a combination of six different boundary conditions; specifically, two oppo...

متن کامل

Modified Structure Function Model Based on Coherent Structures

In the present study, a modified Structure Function was introduced. In this modified Structure Function model, the coefficient of model was computed dynamically base on the coherent structure in the flow field. The ability of this Modified Structure Function was investigated for complex flow over a square cylinder in free stream and a low aspect ratio cylinder confined in a channel. The Results...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2009