Evaluation of the self-inflating bag-valve-mask and non-rebreather mask as preoxygenation devices in volunteers
نویسندگان
چکیده
OBJECTIVE To evaluate and compare the effectiveness and tolerability of preoxygenation with the self-inflating bag-valve-mask (BVM) and non-rebreather mask (NRM) as are used before emergency anaesthesia. DESIGN Device performance evaluation. SETTING Experimental study. PARTICIPANTS 12 male and 12 female healthy volunteers (age range 24-47) with no history of clinically significant respiratory disease. INTERVENTIONS End-expiration oxygen measurements (F(E)O(2)) after 3 min of preoxygenation with BVM (without mechanical assistance) and NRM devices. Mask pressures were measured and subjective difficulty of breathing was also assessed with a visual analogue score (VAS). PRIMARY AND SECONDARY OUTCOME MEASURES The final F(E)O(2) achieved was 58.0% (SD 7.3%) for the NRM compared to 53.1% (SD 13.4%) for the BVM (p=0.072). Preoxygenation was associated with small increases in F(E)CO(2) that were greater for the BVM (0.50%; 95% CI 0.48 to 0.52) than the NRM (0.29%; 95% CI 0.31 to 0.28); this difference was statistically significant (p=0.028). Both devices were well tolerated on VAS assessment of difficulty of breathing although this was higher for the BVM than the NRM (median VAS 1.85/10 compared to 1.1/10; p=0.041). Inspiratory and expiratory mask pressures were higher for the BVM. CONCLUSIONS In healthy volunteers, the NRM performs comparably to the BVM in terms of the degree of denitrogenation achieved although neither performed well. Although it was well tolerated, the BVM was subjectively more difficult to breathe through and was associated with greater mask pressures and a small increase in F(E)CO(2) consistent with hypoventilation or rebreathing. Our results suggest that preoxygenation with the NRM may be a preferable approach in spontaneously breathing patients.
منابع مشابه
Efficacy of Nasal Cannula Oxygen as a Preoxygenation Adjunct in Emergency Airway Management.
STUDY OBJECTIVE Although preoxygenation for emergency airway management is usually performed with nonrebreather face masks or bag-valve-mask devices, some clinicians also deliver supplemental high-flow oxygen by nasal cannula. We aim to measure the efficacy of supplemental nasal cannula oxygen delivery to conventional bag-valve-mask and nonrebreather face mask preoxygenation both with and witho...
متن کاملEmergency airway management by non-anaesthesia house officers--a comparison of three strategies.
OBJECTIVES The purpose of this study was to determine effects of different airway devices and tidal volumes on lung ventilation and gastric inflation in an unprotected airway. METHODS Thirty one non-anaesthesia house officers volunteered for the study, and ventilated a bench model simulating an unintubated respiratory arrest patient with bag-valve-facemask, laryngeal mask airway, and combitub...
متن کاملPreoxygenation via a non-rebreather mask comparing a standard oxygen flowmeter rate of 15 Lpm to maximally open.
Dear Editor, Preoxygenation is critical to safe emergency airway management with an end-tidal oxygen (ETO2) of >90% considered the target prior to induction. Outside of the operating theatre and in prehospital environments, turning open the valve of a standard wall/cylinder outlet past the 15 Lpm graduation (‘overflow’) has been proposed to greatly enhance preoxygenation via a non-rebreather ma...
متن کاملOptimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator.
When ventilating an unintubated patient with a self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressure with subsequent stomach inflation; this may occur frequently when rescuers without daily experience in bag-valve-mask ventilation need to perform advanced airway management. The purpose of this study was to assess the effects of a newly developed self-infla...
متن کاملEmergency airway management by intensive care unit nurses with the intubating laryngeal mask airway and the laryngeal tube
When using the laryngeal tube and the intubating laryngeal mask airway (ILMA), the medium-size (maximum volume 1100 ml) versus adult (maximum volume 1500 ml) self-inflating bags resulted in significantly lower lung tidal volumes. No gastric inflation occurred when using both devices with either ventilation bag. The newly developed medium-size self-inflating bag may be an option to further reduc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -