Clinical evaluation of a medical image management system for chest images.

نویسندگان

  • R L Arenson
  • S B Seshadri
  • H L Kundel
  • D DeSimone
  • F Van der Voorde
  • W B Gefter
  • D M Epstein
  • W T Miller
  • J M Aronchick
  • M B Simson
چکیده

The clinical efficacy and physicians' assessment of a medical image management system (MIMS) for chest images that involved the medical intensive care unit (MICU) and the radiology department were evaluated. A token-passing fiber-optic network was implemented to connect display stations in the MICU and in the chest reading area in the radiology department with a laser film digitizer and an archiving system. To study the clinical efficacy of this system, blocks of 8 weeks during which portable chest images were digitized and immediately made available in the MICU were alternated with blocks of 8 weeks during which film images only were available. Approximately 3000 portable chest examinations were tracked; patients were entered into the study at a rate of 65 per month. Data on time intervals associated with the examination process were collected from MICU physicians, radiologists, radiographers, and film librarians. The time from the completion of an examination to the time an action was taken that was based on radiographic findings showed significant reductions during the digital periods for certain actions. For example, the time to begin drug therapy decreased from a mean of 4.7 hr when films were viewed to a mean of 3.3 hr when digital images were viewed. In conclusion, if prompt action by the MICU physician improves a patient's outcome, a positive effect on patient care will result from the immediate availability of radiographic images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the role of system matrix in SPECT images reconstructed by OSEM technique

  Introduction: Ordered subset expectation maximization (OSEM), is an effective iterative method for SPECT image reconstruction. The aim of this study is the evaluation of the role of system matrix in OSEM image reconstruction method using four different physical beam radiation models with three detection configurations. Methods: SPECT was done with an arc of 180 deg...

متن کامل

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...

متن کامل

Qualitative evaluation of filter function in brain SPECT [Persian]

Introduction: Filtering can greatly affect the quality of clinical images. Determining the best filter and the proper degree of smoothing can help to ensure the most accurate diagnosis. Methods: Forty five patient’s data aquired during brain phantom SPECT studies were reconstructed using filtered back-projection technique. The ramp, Shepp-Logan, Cosine, Hamming, Hanning, Butterworth, Metz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 150 1  شماره 

صفحات  -

تاریخ انتشار 1988