The use of heparin in preparing samples for blood-gas analysis.
نویسنده
چکیده
Heparin is the only anticoagulant used to prepare samples for blood-gas analysis. There are two ways in which heparin can interfere with results. The first is high heparin concentration in blood, and the second is heparin dilution of blood if liquid rather than dried (lyophilized) heparin is used. Traditional blood-gas analytes (pH, pCO2, and pO2) are less affected than electrolytes (particularly ionized calcium), also measured on modern blood-gas analyzers. The sample requirements as far as heparin is concerned are thus less exacting if only pH, pCO2, and pO2 are to be measured. For these analytes, it is still essential that the heparin (either sodium or lithium) concentration is less than 200 IU/mL blood and that the blood is not diluted more than 5%. The inclusion of electrolytes in the test repertoire excludes the use of sodium heparin in favor of lithium heparin. The inclusion of ionized calcium in the test repertoire demands that the heparin should be lyophilized, and the concentration should not exceed 10 IU/mL blood, unless a specialized heparin that eliminates the effect of calcium binding by heparin is used. Whatever the heparin formulation, it is essential for accurate results that the correct volume of blood is sampled to achieve a correct heparin concentration (and dilution, if liquid heparin is used), and that blood and anticoagulant are well mixed immediately after sampling. One of the most common practical problems associated with blood-gas analysis is inadequate anticoagulation and the formation of small blood clots that can block the sample pathway of blood-gas analyzers and invalidate results. Inadequate mixing of specimen with heparin is usually the problem. Clearly, the lower the heparin concentration the greater is the risk that poor mixing technique will give rise to inadequate anticoagulation and the associated problems.
منابع مشابه
y the use of heparin in preparing samples for blood - gas analysis
16 October 2007 ■ MLO www.mlo-online.com T he significance of good practice during the pre-testing phase of clinical-laboratory investigation cannot be overemphasized. The production of high-quality, accurate results, which are clinically useful, depends as much on practice before the patient’s sample reaches the laboratory as it does on the analytical phase within the laboratory. There are few...
متن کاملThe Necessity of Using Heparin in the UltraTag RBC Kit When Tagging Blood for a Nuclear Medicine Study.
The purpose of this research was to evaluate the need to use heparin when preparing an UltraTag red blood cell (RBC) kit for a nuclear medicine study. METHODS Nonheparinized blood samples (n = 15) and heparinized blood samples (n = 15) were added to UltraTag RBC kits. The samples were examined for macroscopic blood clotting and microscopic platelet clumping. As a control, samples with heparin...
متن کاملContamination of coagulation tests with heparin from blood gas samples.
We investigated the possibility that samples of blood could be contaminated by heparinized blood gas syringes, giving spurious results in coagulation tests. We collected coagulation test samples before (n=5) and after (n=13) blood gas sampling from a venous cannula in a volunteer. The results of activated partial thromboplastin time (APTT) tests were compared between control samples and samples...
متن کاملComparative Study of Four Platelet-Rich Plasma Methods for Preparing Platelet Concentrates
Background: Platelet preparations have been used for a wide variety of clinical applications such as hemorrhage, tissue engineering and cellular therapy. Platelet concentrates can be prepared by the apheresis method or from the whole blood using the Buffy-coat or Platelet-rich plasma methods. The purpose of this study was to compare four variations of platelet-rich plasma method based on double...
متن کاملDetermination of Neonatal Prognosis Based on Umbilical Vein Blood Gas in Hakim Hospital of Neyshabur, Iran during 2017-2018
Background: In order to determine the prognosis of neonates, it is recommended to use umbilical gas analysis in all high-risk pregnancies. However, utilizing umbilical gas analysis and Apgar score together is very helpful for determining the mortality rate confidence interval. Therefore, in this study, we investigated the application of umbilical gas analysis in assessing the prognosis of infan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- MLO: medical laboratory observer
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2007