Research on the microstructure of insect cuticle and the strength of a biomimetic preformed hole composite.

نویسندگان

  • B Chen
  • X Peng
  • W Wang
  • J Zhang
  • R Zhang
چکیده

The insect cuticle is a typical natural composite with excellent strength, stiffness, and fracture toughness. Scanning electron microscope observation of the microstructure of Hydrophilidae (an insect) cuticle showed several unique plies and structural characteristics, which may provide available information to the design of advanced composites. The microstructure found in the vicinity of pore canals in the insect cuticle was used for the design of the composite laminate with a hole. Compared with the composite laminate with a normally drilled hole, it was found that the strength of the specially designed composite laminate increases markedly, which is of important significance to the design of high-performance composites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Variation in Fracture Strength and Calculation of Stress Concentration Factor in Composite Laminates with Circular Hole

In this research, residual strength and stress concentration factor of laminated composites with a circular open hole are studied analytically, numerically and experimentally. The numerical study was carried out using the finite element method. Moreover an analytical study was carried out with developing of point stress criterion. Mechanical testing was performed to determine the un-notched ten...

متن کامل

Fracture toughness of locust cuticle.

Insect cuticle is one of the most common biological materials, yet very little is known about its mechanical properties. Many parts of the insect exoskeleton, such as the jumping legs of locusts, have to withstand high and repeated loading without failure. This paper presents the first measurements of fracture toughness for insect cuticle using a standard engineering approach. Our results show ...

متن کامل

Open-Hole Size and Thermal Cycling Effects on Mass Loss and Surface Degradation of Polymer Matrix Composites

Degradation is a common problem for polymer matrix composites (PMCs) under low thermal cycling conditions. This paper investigates the effects of low thermal cycling on total mass loss (TML) and surface degradation of PMCs. Unnotched and open-hole specimens were weighed before and after low thermal cycling. The total mass loss and surface degradation of the specimens were studied over 250 cycle...

متن کامل

A review on stress distribution, strength and failure of bolted ‎composite joints

In this study, analytical models considering different material and geometry for ‎both single and double-lap bolted joints were reviewed for better understand how to ‎select the proper model for a particular application. The survey indicades that the ‎analytic models selected for the adhesively single or double bolted lap joints, as well ‎as T, scarf, and stepped joints, with linear material pr...

متن کامل

Manufacturing a Biomimetic Biorecator in Cardiac Tissue Engineering

Introduction: The direct approach of cardiac tissue engineering is to mimic the natural tissue of heart, considering the significant role of scaffolding and mechanical simulation.  Methods: To achieve this purpose, a composite Polycaprolactone (PCL)/Gelatin electrospun scaffold with a ratio of 70:30 and with the most similarities to the cardiac extracellular matrix was fabricated with aligned ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Micron

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2002