Comparison of inflammatory response after implantation of sirolimus- and paclitaxel-eluting stents in porcine coronary arteries.

نویسندگان

  • Gregory J Wilson
  • Gaku Nakazawa
  • Robert S Schwartz
  • Barbara Huibregtse
  • Bradley Poff
  • Thomas J Herbst
  • Donald S Baim
  • Renu Virmani
چکیده

BACKGROUND Although both sirolimus (CYPHER) and paclitaxel (TAXUS) drug-eluting stents have demonstrated efficacy and safety in clinical trials, human autopsy data have raised concerns about long-term healing and the potential for local inflammatory reactions. METHODS AND RESULTS Overlapping stents (CYPHER drug-eluting stents, Bx SONIC bare metal stents, TAXUS drug-eluting stents, and Liberté bare metal stents) were implanted in noninjured coronary arteries of 58 domestic swine. Histopathological evaluation of proximal, overlapped, and distal stented segments was determined with emphasis on inflammation at 30, 90, and 180 days. Circumferential granulomatous inflammation in all stented segments was defined as inflammation consisting of macrophages, multinucleated giant cells, lymphocytes, and granulocytes, including many eosinophils, adjacent to almost all struts. Circumferential granulomatous inflammation was more prevalent in CYPHER (9 of 23, 39%) compared with TAXUS (1 of 21, 5%; P=0.01) and control bare metal stents (0 of 44) in the combined 90- and 180-day cohorts. Only CYPHER specimens showed marked adventitial inflammation (P=0.0025) and fibrosis (P=0.0055) accompanied by extensive remodeling. Fibrin deposition within neointima and medial smooth muscle cell death were greater (both P<0.001) in TAXUS than CYPHER at 30 days, with more fibrin in TAXUS than CYPHER through 90 days (P<0.05). CONCLUSIONS Although these data cannot be directly extrapolated to humans, the high prevalence in this porcine model of diffuse granulomatous inflammation seen with CYPHER stents, persisting at 180 days and associated with extensive remodeling of the artery, and persistent para-strut fibrin deposition with TAXUS stents emphasize the need for further investigation of biocompatibility with these and other novel combination drug/polymer drug-eluting stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

Late device thrombosis after atrial septal defect closure.

Kay IP, Ligthart JM, Thayssen P, van Den Brand MJ, de Feyter PJ, Serruys PW. Three dimensional intravascular ultrasonic assessment of the local mechanism of restenosis after balloon angioplasty. Heart 2001;85:73–79. 5. Costa MA, Simon DI. Molecular basis of restenosis and drug-eluting stents. Circulation 2005;111:2257–2273. 6. van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruy...

متن کامل

Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.

BACKGROUND Biodegradable polymer-coated stents may have positive effects on arterial healing, and reduce the need for prolonged antiplatelet therapy. AIM To assess the vascular effects of the biodegradable polymer proposed as a stent coating, as well as to evaluate inhibition of intimal hyperplasia by Biodegradable Polymer-Coated Paclitaxel-Eluting Stents (BP-PES, LUC-Chopin, Balton) in porci...

متن کامل

Inflammation and delayed endothelization with overlapping drug-eluting stents in a porcine model of in-stent restenosis.

BACKGROUND This study evaluated the inflammatory reaction at the site of overlapping drug-eluting stents (DES) in a porcine model of in-stent restenosis. METHODS AND RESULTS Twenty bare metal stents (BMS) (group I; n=10), 20 sirolimus-eluting stents (SES) (group II: n=10), 20 paclitaxel-eluting stent (PES) (group III: n=10), and 10 PES and 10 SES (group IV: n=10) were overlapped in the left a...

متن کامل

Anti-inflammatory Effect of Abciximab-Coated Stent in a Porcine Coronary Restenosis Model

The aim of this study was to examine the anti-inflammatory effect of abciximab-coated stent in a porcine coronary overstretch restenosis model. Ten abciximab-coated stents, ten sirolimus-eluting stents (SES), and ten paclitaxel-eluting stents (PES) were deployed with oversizing (stent/artery ratio 1.3:1) in porcine coronary arteries, and histopathologic analysis was done at 28 days after stenti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 120 2  شماره 

صفحات  -

تاریخ انتشار 2009